{"id":99711,"date":"2026-11-16T08:53:16","date_gmt":"2026-11-16T08:53:16","guid":{"rendered":"https:\/\/www.keyter.com\/rite-la-trampa-de-los-70kw\/"},"modified":"2026-11-16T11:05:49","modified_gmt":"2026-11-16T11:05:49","slug":"rite-la-trampa-de-los-70kw","status":"publish","type":"page","link":"https:\/\/www.keyter.com\/es\/rite-la-trampa-de-los-70kw\/","title":{"rendered":"RITE, la Trampa de los 70kW"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"99711\" class=\"elementor elementor-99711 elementor-99706\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-86c0b10 elementor-section-stretched elementor-section-full_width elementor-section-height-default elementor-section-height-default parallax_section_no qode_elementor_container_no\" data-id=\"86c0b10\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;stretch_section&quot;:&quot;section-stretched&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-18517a8\" data-id=\"18517a8\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-1a1559a e-grid-align-right elementor-shape-rounded elementor-grid-0 elementor-widget elementor-widget-social-icons\" data-id=\"1a1559a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"social-icons.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-social-icons-wrapper elementor-grid\" role=\"list\">\n\t\t\t\t\t\t\t<span class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t<a class=\"elementor-icon elementor-social-icon elementor-social-icon-linkedin elementor-repeater-item-a8c6510\" href=\"https:\/\/es.linkedin.com\/company\/keyter\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-screen-only\">Linkedin<\/span>\n\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fab fa-linkedin\"><\/i>\t\t\t\t\t<\/a>\n\t\t\t\t<\/span>\n\t\t\t\t\t\t\t<span class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t<a class=\"elementor-icon elementor-social-icon elementor-social-icon-facebook elementor-repeater-item-3362250\" href=\"https:\/\/www.facebook.com\/keyterHVACR\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-screen-only\">Facebook<\/span>\n\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fab fa-facebook\"><\/i>\t\t\t\t\t<\/a>\n\t\t\t\t<\/span>\n\t\t\t\t\t\t\t<span class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t<a class=\"elementor-icon elementor-social-icon elementor-social-icon-x-twitter elementor-repeater-item-3f1e49f\" href=\"https:\/\/twitter.com\/KEYTERes\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-screen-only\">X-twitter<\/span>\n\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fab fa-x-twitter\"><\/i>\t\t\t\t\t<\/a>\n\t\t\t\t<\/span>\n\t\t\t\t\t\t\t<span class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t<a class=\"elementor-icon elementor-social-icon elementor-social-icon-youtube elementor-repeater-item-2b5a944\" href=\"https:\/\/www.youtube.com\/channel\/UCMHOMneQyaueda5RocUOBog\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-screen-only\">Youtube<\/span>\n\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fab fa-youtube\"><\/i>\t\t\t\t\t<\/a>\n\t\t\t\t<\/span>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-40a7448 elementor-widget elementor-widget-html\" data-id=\"40a7448\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<meta charset=\"utf-8\"\/><meta content=\"width=device-width, initial-scale=1\" name=\"viewport\"\/>\r\n<style>\r\n@import url(\"https:\/\/fonts.googleapis.com\/css2?family=Asap:wght@400;500;600;700;800&display=swap\");\r\n\/* KEYTER \/ Instituto Entalpico Espanol - plantilla editorial para Elementor. *\/\r\n#rite-70kw-article{--une-green:#72b431;--une-dark:#18212b;--une-muted:#5e6873;--une-line:#e6e8ea;--une-navy:#153c58;--une-blue:#225982;--une-pale:#f1f6f9;box-sizing:border-box;container-type:inline-size;container-name:rite70Article;width:100%;max-width:1180px;margin:0 auto;padding:12px 10px 48px;background:transparent;color:#111;font-family:'Asap',sans-serif;font-size:14px;line-height:26px}\r\n#rite-70kw-article *,#rite-70kw-article *::before,#rite-70kw-article *::after{box-sizing:border-box}\r\n#rite-70kw-article .une-t{display:none!important}\r\n#rite-70kw-article .une-t[lang=\"es\"]{display:inline!important}\r\nhtml:lang(en) #rite-70kw-article .une-t[lang=\"es\"],html:lang(fr) #rite-70kw-article .une-t[lang=\"es\"],html:lang(it) #rite-70kw-article .une-t[lang=\"es\"],html:lang(de) #rite-70kw-article .une-t[lang=\"es\"]{display:none!important}\r\nhtml:lang(en) #rite-70kw-article .une-t[lang=\"en\"],html:lang(fr) #rite-70kw-article .une-t[lang=\"fr\"],html:lang(it) #rite-70kw-article .une-t[lang=\"it\"],html:lang(de) #rite-70kw-article .une-t[lang=\"de\"]{display:inline!important}\r\n#rite-70kw-article h1,#rite-70kw-article h2,#rite-70kw-article h3{font-family:'Asap',sans-serif!important;color:var(--une-dark)!important;font-weight:700!important;line-height:26px!important;text-transform:none!important;letter-spacing:normal!important;margin:0;overflow-wrap:break-word}\r\n#rite-70kw-article h1{font-size:28px!important;line-height:1.28!important;margin:0 0 13px!important}\r\n#rite-70kw-article h2,#rite-70kw-article h3{font-size:16px!important;line-height:26px!important;font-weight:700!important}\r\n#rite-70kw-article p{margin:0 0 14px}\r\n#rite-70kw-article strong{font-weight:700}\r\n#rite-70kw-article .une-article-header{margin:0 0 21px}\r\n#rite-70kw-article .une-title-mark{display:block;line-height:0;margin:7px 0 0!important}\r\n#rite-70kw-article .une-title-mark img{display:block;width:300px;max-width:100%;height:auto;max-height:22px;object-fit:contain;object-position:left center;border:0}\r\n#rite-70kw-article .une-hero-lead{max-width:1100px;margin:20px auto 26px;text-align:center;font-weight:700;font-style:italic}\r\n#rite-70kw-article .une-hero-lead p{margin:0 0 11px}\r\n#rite-70kw-article .une-page-group{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:30px;align-items:start;margin:30px 0 0;clear:both}\r\n#rite-70kw-article .une-page-group--separated{padding-top:27px;border-top:1px solid var(--une-line)}\r\n#rite-70kw-article .une-column{min-width:0}\r\n#rite-70kw-article .rite-block-heading{color:#e3262e!important;font-size:16px!important;line-height:26px!important;margin:0 0 13px!important}\r\n#rite-70kw-article .rite-conclusion{max-width:1080px;margin:32px auto 24px;text-align:center}\r\n#rite-70kw-article .rite-conclusion-title{text-align:center;font-size:16px!important;margin:0 0 14px!important}\r\n#rite-70kw-article .rite-conclusion p{font-weight:700;font-style:italic;margin:0 0 14px}\r\n#rite-70kw-article .une-multilingual-motto{max-width:940px;margin:27px auto 29px;text-align:center;font-weight:700;font-style:italic}\r\n#rite-70kw-article .une-table-wrap{margin:24px 0 26px;overflow-x:auto;max-width:100%}\r\n#rite-70kw-article table.une-limits-table{width:100%;min-width:690px;border-collapse:collapse;font-family:'Asap',sans-serif;font-size:14px;line-height:26px}\r\n#rite-70kw-article .une-limits-table th{padding:9px 10px;background:#8bd7f1;color:#111!important;text-align:left;font-size:14px;font-weight:700;line-height:26px;vertical-align:middle;border:1px solid #a8c8d5}\r\n#rite-70kw-article .une-limits-table td{padding:9px 10px;text-align:left;vertical-align:middle;border:1px solid #cbd5dc;background:#fff}\r\n#rite-70kw-article .une-limits-table tr:nth-child(even) td{background:#f0f2f4}\r\n#rite-70kw-article .une-limits-table td:first-child{font-weight:700}\r\n#rite-70kw-article .pree-author-card{display:block!important;width:100%!important;max-width:960px!important;padding:16px 18px!important;border:1px solid #e2e2e2!important;border-radius:10px!important;background:transparent!important;box-shadow:none!important;color:#111!important;font:normal 14px\/26px 'Asap',sans-serif!important;clear:both!important}\r\n#rite-70kw-article .pree-author-card--top{margin:18px 0 0!important}\r\n#rite-70kw-article .pree-author-card--bottom{margin:20px 0 12px!important}\r\n#rite-70kw-article .pree-author-card .pree-author-identity{display:grid!important;grid-template-columns:58px minmax(0,1fr) 150px!important;grid-template-rows:auto!important;align-items:center!important;column-gap:14px!important;row-gap:8px!important;width:100%!important;max-width:100%!important;min-width:0!important}\r\n#rite-70kw-article .pree-author-card .keyter-author-compact__photo{position:static!important;display:block!important;grid-column:1!important;grid-row:1!important;width:58px!important;min-width:58px!important;max-width:58px!important;height:58px!important;min-height:58px!important;max-height:58px!important;object-fit:cover!important;border-radius:50%!important;margin:0!important;padding:0!important}\r\n#rite-70kw-article .pree-author-card .keyter-author-compact__content{grid-column:2!important;grid-row:1!important;min-width:0!important;max-width:none!important;width:auto!important;margin:0!important;padding:0!important;text-align:left!important;font-family:'Asap',sans-serif!important}\r\n#rite-70kw-article .pree-author-card .keyter-author-compact__name{font:700 16px\/26px 'Asap',sans-serif!important;color:#111!important;margin:0 0 2px!important;padding:0!important}\r\n#rite-70kw-article .pree-author-card .keyter-author-compact__meta,#rite-70kw-article .pree-author-card .keyter-author-compact__bio{font:400 14px\/26px 'Asap',sans-serif!important;color:#666!important;margin:0!important;padding:0!important}\r\n#rite-70kw-article .pree-author-card .keyter-author-compact__links{font:400 14px\/26px 'Asap',sans-serif!important;color:#555!important;margin:4px 0 0!important;padding:0!important;overflow-wrap:anywhere!important}\r\n#rite-70kw-article .pree-author-card .keyter-author-compact__links a{color:#72b431!important;text-decoration:underline!important;text-underline-offset:2px!important}\r\n#rite-70kw-article .pree-author-card .pree-iee-logo--author{display:flex!important;grid-column:3!important;grid-row:1!important;align-self:center!important;justify-self:end!important;align-items:center!important;justify-content:center!important;width:150px!important;min-width:0!important;max-width:150px!important;height:auto!important;margin:0!important;padding:0!important;border:0!important;text-decoration:none!important}\r\n#rite-70kw-article .pree-author-card .pree-iee-logo--author img{display:block!important;width:150px!important;max-width:100%!important;height:auto!important;max-height:92px!important;object-fit:contain!important;margin:0!important;padding:0!important;border:0!important}\r\n#rite-70kw-article .une-norm-tags{width:100%;max-width:960px;margin:9px 0 20px;font-family:'Asap',sans-serif}\r\n#rite-70kw-article .une-norm-tags__grid{display:flex;flex-wrap:wrap;justify-content:flex-start;align-items:stretch;gap:7px}\r\n#rite-70kw-article a.une-norm-tags__item{display:flex;flex:0 1 auto;justify-content:center;align-items:center;width:auto;min-height:34px;padding:7px 8px;border:1px solid #cfdce6;border-radius:5px;background:#f3f8fb;color:#72b431!important;text-decoration:none!important;font:700 14px\/18px 'Asap',sans-serif!important;text-align:center;overflow-wrap:anywhere}\r\n#rite-70kw-article a.une-norm-tags__item:hover{background:#e6f1f7;border-color:#7ba9c4;text-decoration:underline!important}\r\n#rite-70kw-article a:focus-visible{outline:2px solid var(--une-green);outline-offset:3px}\r\n#rite-70kw-article a{overflow-wrap:anywhere}\r\n@container rite70Article (max-width:760px){#rite-70kw-article .une-page-group{grid-template-columns:minmax(0,1fr);gap:8px}#rite-70kw-article .pree-author-card .pree-author-identity{grid-template-columns:50px minmax(0,1fr)!important;grid-template-rows:auto auto!important;align-items:start!important;gap:9px 12px!important}#rite-70kw-article .pree-author-card .keyter-author-compact__photo{width:50px!important;min-width:50px!important;max-width:50px!important;height:50px!important;min-height:50px!important;max-height:50px!important}#rite-70kw-article .pree-author-card .pree-iee-logo--author{grid-column:2!important;grid-row:2!important;justify-self:start!important;width:125px!important;max-width:125px!important;margin:4px 0 0!important}#rite-70kw-article .pree-author-card .pree-iee-logo--author img{width:125px!important}}\r\n@media(max-width:767px){#rite-70kw-article{padding:12px 8px 29px}#rite-70kw-article .une-page-group{grid-template-columns:minmax(0,1fr);gap:8px}#rite-70kw-article .une-hero-lead{margin:17px 0 21px}#rite-70kw-article .une-table-wrap{margin:19px 0 22px}#rite-70kw-article .pree-author-card .pree-author-identity{grid-template-columns:50px minmax(0,1fr)!important;grid-template-rows:auto auto!important;align-items:start!important;gap:9px 12px!important}#rite-70kw-article .pree-author-card .keyter-author-compact__photo{width:50px!important;min-width:50px!important;max-width:50px!important;height:50px!important;min-height:50px!important;max-height:50px!important}#rite-70kw-article .pree-author-card .pree-iee-logo--author{grid-column:2!important;grid-row:2!important;justify-self:start!important;width:125px!important;max-width:125px!important;margin:4px 0 0!important}#rite-70kw-article .pree-author-card .pree-iee-logo--author img{width:125px!important}}\r\n@media print{#rite-70kw-article{max-width:none}#rite-70kw-article .pree-author-card,#rite-70kw-article .une-table-wrap{break-inside:avoid}}\r\n\/* Ajuste de tipografia replicado de FGAS_Elementor_FINAL_PDF_VERDE_AUTOR_IDIOMAS.html. *\/\r\n#rite-70kw-article#rite-70kw-article,#rite-70kw-article#rite-70kw-article :where(*){font-family:'Asap',sans-serif!important;font-size:14px!important;line-height:26px!important}\r\n#rite-70kw-article#rite-70kw-article h1,#rite-70kw-article#rite-70kw-article h1 :where(*){font-size:28px!important;line-height:1.28!important;font-weight:700!important}\r\n#rite-70kw-article#rite-70kw-article h2,#rite-70kw-article#rite-70kw-article h2 :where(*),#rite-70kw-article#rite-70kw-article h3,#rite-70kw-article#rite-70kw-article h3 :where(*){font-size:16px!important;line-height:26px!important;font-weight:700!important}\r\n#rite-70kw-article#rite-70kw-article .keyter-author-compact__name{font-size:16px!important;line-height:26px!important;font-weight:700!important}\r\n\r\n\/* FIDELIDAD FGAS: etiquetas normativas y enlaces en el verde corporativo.\r\n   Misma especificidad y jerarquia visual de la plantilla FGAS revisada.\r\n   Evita que la regla general de 26px o los estilos de Elementor modifiquen las etiquetas. *\/\r\n#rite-70kw-article#rite-70kw-article a:link:not(.pree-iee-logo--author),\r\n#rite-70kw-article#rite-70kw-article a:visited:not(.pree-iee-logo--author){color:#72b431!important}\r\n#rite-70kw-article#rite-70kw-article .une-norm-tags__grid{\r\n  display:flex!important;flex-wrap:wrap!important;justify-content:flex-start!important;\r\n  align-items:stretch!important;gap:7px!important\r\n}\r\n#rite-70kw-article#rite-70kw-article a.une-norm-tags__item,\r\n#rite-70kw-article#rite-70kw-article a.une-norm-tags__item:link,\r\n#rite-70kw-article#rite-70kw-article a.une-norm-tags__item:visited{\r\n  display:flex!important;flex:0 1 auto!important;align-items:center!important;justify-content:center!important;\r\n  width:auto!important;min-height:34px!important;padding:7px 8px!important;\r\n  border:1px solid #cfdce6!important;border-radius:5px!important;\r\n  background:#f3f8fb!important;color:#72b431!important;\r\n  font-family:'Asap',sans-serif!important;font-size:14px!important;\r\n  line-height:18px!important;font-weight:700!important;\r\n  text-align:center!important;text-decoration:none!important\r\n}\r\n#rite-70kw-article#rite-70kw-article a.une-norm-tags__item:hover,\r\n#rite-70kw-article#rite-70kw-article a.une-norm-tags__item:focus-visible{\r\n  background:#e6f1f7!important;border-color:#7ba9c4!important;\r\n  color:#72b431!important;text-decoration:underline!important\r\n}\r\n#rite-70kw-article#rite-70kw-article .une-norm-tags--bottom{margin:9px 0 20px!important}\r\n<\/style>\r\n<div class=\"une-article-text\" id=\"rite-70kw-article\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Article\">\r\n<header class=\"une-article-header\"><h1 itemprop=\"headline\"><span class=\"une-t\" lang=\"es\">RITE, LA TRAMPA DE LOS 70kW<\/span><span class=\"une-t\" lang=\"en\">RITE: THE 70 kW TRAP<\/span><span class=\"une-t\" lang=\"fr\">RITE : LE PI\u00c8GE DES 70 kW<\/span><span class=\"une-t\" lang=\"it\">RITE: LA TRAPPOLA DEI 70 kW<\/span><span class=\"une-t\" lang=\"de\">RITE: DIE 70-kW-FALLE<\/span><\/h1><div aria-hidden=\"true\" class=\"une-title-mark\"><img decoding=\"async\" alt=\"\" height=\"20\" loading=\"eager\" src=\"https:\/\/www.keyter.com\/wp-content\/uploads\/2020\/11\/line-leaf-single-right.svg\" width=\"300\"\/><\/div>\r\n<aside aria-label=\"Autor\" class=\"pree-author-card pree-author-card--top\"><div class=\"pree-author-identity\"><img loading=\"lazy\" alt=\"Jos\u00e9 Jes\u00fas Arboledas Herranz\" class=\"keyter-author-compact__photo\" decoding=\"async\" height=\"58\" loading=\"lazy\" src=\"https:\/\/www.keyter.com\/wp-content\/uploads\/2026\/10\/1791098996839.jpg\" width=\"58\"\/><div class=\"keyter-author-compact__content\"><p class=\"keyter-author-compact__name\">Jos\u00e9 Jes\u00fas Arboledas Herranz<\/p><p class=\"keyter-author-compact__meta\">Instituto Ent\u00e1lpico Espa\u00f1ol<\/p><p class=\"keyter-author-compact__bio\"><span class=\"une-t\" lang=\"es\">Miembro ASHRAE Spain Chapter<\/span><span class=\"une-t\" lang=\"en\">ASHRAE Spain Chapter member<\/span><span class=\"une-t\" lang=\"fr\">Membre de l\u2019ASHRAE Spain Chapter<\/span><span class=\"une-t\" lang=\"it\">Membro di ASHRAE Spain Chapter<\/span><span class=\"une-t\" lang=\"de\">Mitglied des ASHRAE Spain Chapter<\/span><\/p><p class=\"keyter-author-compact__links\"><a href=\"mailto:iee@institutoentalpico.com\">iee@institutoentalpico.com<\/a> \u00b7 <a href=\"https:\/\/lnkd.in\/p\/emk_G3xH\" rel=\"noopener noreferrer\" target=\"_blank\">LinkedIn<\/a> \u00b7 <a href=\"https:\/\/www.youtube.com\/@institutoentalpicoespa%C3%B1ol\" rel=\"noopener noreferrer\" target=\"_blank\">YouTube<\/a><\/p><\/div><a class=\"pree-iee-logo--author\" href=\"https:\/\/sites.google.com\/view\/institutoentalpico\" rel=\"noopener noreferrer\" target=\"_blank\"><img loading=\"lazy\" alt=\"Instituto Ent\u00e1lpico Espa\u00f1ol\" decoding=\"async\" height=\"70\" loading=\"lazy\" src=\"https:\/\/www.keyter.com\/wp-content\/uploads\/2026\/10\/institutoentalpico-logo.webp\" width=\"180\"\/><\/a><\/div><\/aside>\r\n<nav aria-label=\"Documentaci\u00f3n oficial\" class=\"une-norm-tags une-norm-tags--top\"><div class=\"une-norm-tags__grid\"><a class=\"une-norm-tags__item\" href=\"https:\/\/www.boe.es\/buscar\/pdf\/2007\/BOE-A-2007-15820-consolidado.pdf\" rel=\"noopener noreferrer\" target=\"_blank\">RITE \u00b7 RD 1027\/2007 \u00b7 BOE PDF<\/a><a class=\"une-norm-tags__item\" href=\"https:\/\/www.boe.es\/buscar\/pdf\/2019\/BOE-A-2019-15228-consolidado.pdf\" rel=\"noopener noreferrer\" target=\"_blank\">RSIF \u00b7 RD 552\/2019 \u00b7 BOE PDF<\/a><a class=\"une-norm-tags__item\" href=\"https:\/\/industria.gob.es\/Calidad-Industrial\/seguridadindustrial\/instalacionesindustriales\/instaciones-frigorificas\/Documents\/GUIA%20IF%20NIPO%20v4.pdf\" rel=\"noopener noreferrer\" target=\"_blank\">Guia RSIF \u00b7 Consulta 74 \u00b7 Ministerio<\/a><\/div><\/nav><\/header>\r\n<div class=\"une-hero-lead\">\r\n<p><span class=\"une-t\" lang=\"es\">Una instalaci\u00f3n de climatizaci\u00f3n con menos de 70 kW de potencia t\u00e9rmica puede necesitar proyecto.<\/span><span class=\"une-t\" lang=\"en\">An air-conditioning installation with less than 70 kW of thermal capacity may require a project.<\/span><span class=\"une-t\" lang=\"fr\">Une installation de climatisation de moins de 70 kW de puissance thermique peut n\u00e9cessiter un projet.<\/span><span class=\"une-t\" lang=\"it\">Un impianto di climatizzazione con meno di 70 kW di potenza termica pu\u00f2 richiedere un progetto.<\/span><span class=\"une-t\" lang=\"de\">Eine Klimaanlage mit weniger als 70 kW thermischer Leistung kann ein Projekt erfordern.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">Aunque el RITE permite recurrir a una memoria t\u00e9cnica en ese rango, la aplicaci\u00f3n concurrente del RSIF puede exigir proyecto por las caracter\u00edsticas de la instalaci\u00f3n frigor\u00edfica.<\/span><span class=\"une-t\" lang=\"en\">Although the RITE allows a technical memorandum in that range, the concurrent application of the RSIF may require a project because of the characteristics of the refrigeration installation.<\/span><span class=\"une-t\" lang=\"fr\">Bien que le RITE permette une m\u00e9moire technique dans cette plage, l\u2019application conjointe du RSIF peut exiger un projet en raison des caract\u00e9ristiques de l\u2019installation frigorifique.<\/span><span class=\"une-t\" lang=\"it\">Sebbene il RITE consenta una memoria tecnica in tale intervallo, l\u2019applicazione congiunta del RSIF pu\u00f2 richiedere un progetto per le caratteristiche dell\u2019impianto frigorifero.<\/span><span class=\"une-t\" lang=\"de\">Obwohl das RITE in diesem Bereich eine technische Dokumentation zul\u00e4sst, kann die gleichzeitige Anwendung des RSIF aufgrund der Eigenschaften der K\u00e4lteanlage ein Projekt erfordern.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">Tambi\u00e9n existe otra situaci\u00f3n que conviene distinguir: necesitar un t\u00e9cnico titulado competente sin que resulte obligatorio redactar un proyecto. En determinadas instalaciones con refrigerantes A2L, el RSIF mantiene la memoria t\u00e9cnica, pero exige que dicho t\u00e9cnico firme la justificaci\u00f3n de seguridad cuando concurren los supuestos reglamentarios. Potencia t\u00e9rmica, documentaci\u00f3n exigible y competencia profesional son cuestiones relacionadas, pero no equivalentes.<\/span><span class=\"une-t\" lang=\"en\">There is another situation worth distinguishing: a competent qualified technician may be required even when a project is not mandatory. For certain installations using A2L refrigerants, the RSIF retains the technical memorandum but requires that technician to sign the safety justification when the regulatory conditions apply. Thermal capacity, required documentation and professional competence are related, but they are not equivalent.<\/span><span class=\"une-t\" lang=\"fr\">Il faut aussi distinguer une autre situation : l\u2019intervention d\u2019un technicien qualifi\u00e9 comp\u00e9tent peut \u00eatre requise sans qu\u2019un projet soit obligatoire. Pour certaines installations utilisant des r\u00e9frig\u00e9rants A2L, le RSIF maintient la m\u00e9moire technique, mais exige que ce technicien signe la justification de s\u00e9curit\u00e9 lorsque les conditions r\u00e9glementaires sont r\u00e9unies. Puissance thermique, documentation exig\u00e9e et comp\u00e9tence professionnelle sont li\u00e9es, mais ne sont pas \u00e9quivalentes.<\/span><span class=\"une-t\" lang=\"it\">Occorre distinguere anche un\u2019altra situazione: pu\u00f2 essere necessario un tecnico abilitato competente senza che sia obbligatorio redigere un progetto. In determinate installazioni con refrigeranti A2L, il RSIF mantiene la memoria tecnica, ma richiede che il tecnico firmi la giustificazione di sicurezza quando ricorrono i presupposti regolamentari. Potenza termica, documentazione richiesta e competenza professionale sono aspetti collegati, ma non equivalenti.<\/span><span class=\"une-t\" lang=\"de\">Ein weiterer Fall ist zu unterscheiden: Ein qualifizierter fachkundiger Techniker kann erforderlich sein, obwohl kein Projekt vorgeschrieben ist. Bei bestimmten Anlagen mit A2L-K\u00e4ltemitteln sieht das RSIF weiterhin eine technische Dokumentation vor, verlangt aber, dass der Techniker die Sicherheitsbegr\u00fcndung unterzeichnet, wenn die gesetzlichen Voraussetzungen vorliegen. W\u00e4rmeleistung, erforderliche Unterlagen und berufliche Qualifikation h\u00e4ngen zusammen, sind jedoch nicht gleichbedeutend.<\/span><\/p>\r\n<\/div>\r\n<section aria-label=\"Contenido inicial\" class=\"une-page-group\"><div class=\"une-column\">\r\n<p><span class=\"une-t\" lang=\"es\">\u00abNo llega a 70 kW; con una memoria basta\u00bb. La frase puede ser correcta y, al mismo tiempo, conducir a una tramitaci\u00f3n incompleta. El problema aparece cuando quien la pronuncia aplica el umbral del RITE como si resolviera todas las obligaciones de la instalaci\u00f3n.<\/span><span class=\"une-t\" lang=\"en\">\u201cIt does not reach 70 kW; a memorandum is enough.\u201d The statement may be correct and still lead to incomplete documentation. The problem arises when the RITE threshold is applied as if it resolved every obligation relating to the installation.<\/span><span class=\"une-t\" lang=\"fr\">\u00ab Elle n\u2019atteint pas 70 kW ; une m\u00e9moire suffit \u00bb. La phrase peut \u00eatre exacte et conduire n\u00e9anmoins \u00e0 un dossier incomplet. Le probl\u00e8me apparait lorsque le seuil du RITE est appliqu\u00e9 comme s\u2019il regissait toutes les obligations de l\u2019installation.<\/span><span class=\"une-t\" lang=\"it\">\u00abNon arriva a 70 kW; basta una memoria\u00bb. La frase pu\u00f2 essere corretta e, allo stesso tempo, portare a una pratica incompleta. Il problema nasce quando la soglia del RITE viene applicata come se risolvesse tutti gli obblighi dell\u2019impianto.<\/span><span class=\"une-t\" lang=\"de\">\u201eSie erreicht keine 70 kW; eine Dokumentation gen\u00fcgt.\u201c Die Aussage kann richtig sein und dennoch zu unvollst\u00e4ndigen Unterlagen fuehren. Das Problem entsteht, wenn der RITE-Grenzwert so angewendet wird, als l\u00f6se er saemtliche Pflichten der Anlage.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">Una bomba de calor puede necesitar memoria por su potencia t\u00e9rmica y proyecto por las caracter\u00edsticas de su circuito frigor\u00edfico. Tambi\u00e9n existe una tercera situaci\u00f3n, menos conocida: basta una memoria, pero determinados c\u00e1lculos, justificaciones o an\u00e1lisis requieren la intervenci\u00f3n de un t\u00e9cnico titulado competente.<\/span><span class=\"une-t\" lang=\"en\">A heat pump may require a memorandum because of its thermal capacity and a project because of the characteristics of its refrigeration circuit. There is also a less familiar third situation: a memorandum is sufficient, but certain calculations, justifications or analyses require the involvement of a competent qualified technician.<\/span><span class=\"une-t\" lang=\"fr\">Une pompe \u00e0 chaleur peut relever d\u2019une m\u00e9moire en raison de sa puissance thermique et exiger un projet en raison des caract\u00e9ristiques de son circuit frigorifique. Il existe aussi une troisi\u00e8me situation, moins connue : une m\u00e9moire suffit, mais certains calculs, justifications ou analyses n\u00e9cessitent l\u2019intervention d\u2019un technicien qualifi\u00e9 comp\u00e9tent.<\/span><span class=\"une-t\" lang=\"it\">Una pompa di calore pu\u00f2 richiedere una memoria per la propria potenza termica e un progetto per le caratteristiche del circuito frigorifero. Esiste anche una terza situazione, meno nota: basta una memoria, ma determinati calcoli, giustificazioni o analisi richiedono l\u2019intervento di un tecnico abilitato competente.<\/span><span class=\"une-t\" lang=\"de\">Eine W\u00e4rmepumpe kann aufgrund ihrer thermischen Leistung eine Dokumentation und aufgrund der Eigenschaften ihres K\u00e4ltekreislaufs ein Projekt erfordern. Es gibt auch einen weniger bekannten dritten Fall: Eine Dokumentation reicht aus, bestimmte Berechnungen, Begr\u00fcndungen oder Analysen erfordern jedoch die Mitwirkung eines qualifizierten fachkundigen Technikers.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">Antes de discutir documentos, hay que identificar qu\u00e9 potencia estamos comparando. El art\u00edculo 15.1.b del RITE permite sustituir el proyecto por una memoria cuando la potencia t\u00e9rmica nominal en generaci\u00f3n de calor o fr\u00edo est\u00e1 comprendida entre 5 y 70 kW, ambos incluidos. Exactamente 70 kW sigue dentro de ese intervalo.<\/span><span class=\"une-t\" lang=\"en\">Before discussing documents, it is necessary to identify which power value is being compared. Article 15.1(b) of the RITE allows a project to be replaced by a memorandum when the nominal thermal output for heating or cooling generation is between 5 and 70 kW, inclusive. Exactly 70 kW remains within that range.<\/span><span class=\"une-t\" lang=\"fr\">Avant d\u2019examiner les documents, il faut identifier la puissance compar\u00e9e. L\u2019article 15.1.b du RITE permet de remplacer le projet par une m\u00e9moire lorsque la puissance thermique nominale de production de chaleur ou de froid est comprise entre 5 et 70 kW inclus. Exactement 70 kW reste dans cette plage.<\/span><span class=\"une-t\" lang=\"it\">Prima di discutere i documenti, occorre identificare quale potenza si sta confrontando. L\u2019articolo 15.1.b del RITE consente di sostituire il progetto con una memoria quando la potenza termica nominale di generazione di caldo o freddo \u00e8 compresa tra 5 e 70 kW, estremi inclusi. Esattamente 70 kW rientra ancora in tale intervallo.<\/span><span class=\"une-t\" lang=\"de\">Bevor die Unterlagen betrachtet werden, muss klar sein, welche Leistung verglichen wird. Artikel 15.1.b des RITE erlaubt es, das Projekt durch eine Dokumentation zu ersetzen, wenn die thermische Nennleistung der W\u00e4rme- oder Kaelteerzeugung zwischen 5 und 70 kW einschliesslich liegt. Genau 70 kW liegt weiterhin innerhalb dieses Bereichs.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">Adem\u00e1s, el art\u00edculo 15.2 establece c\u00f3mo sumar generadores que cubren el servicio: dividir una instalaci\u00f3n entre varias m\u00e1quinas no permite revisar cada placa de manera aislada.<\/span><span class=\"une-t\" lang=\"en\">In addition, Article 15(2) establishes how generators serving the same function are to be added together: dividing an installation among several machines does not allow each nameplate to be assessed in isolation.<\/span><span class=\"une-t\" lang=\"fr\">En outre, l\u2019article 15.2 pr\u00e9cise comment additionner les g\u00e9n\u00e9rateurs qui assurent le service : r\u00e9partir une installation entre plusieurs machines ne permet pas d\u2019examiner chaque plaque signal\u00e9tique isol\u00e9ment.<\/span><span class=\"une-t\" lang=\"it\">Inoltre, l\u2019articolo 15.2 stabilisce come sommare i generatori che coprono il servizio: suddividere un impianto tra pi\u00f9 macchine non consente di valutare ogni targa separatamente.<\/span><span class=\"une-t\" lang=\"de\">Ausserdem legt Artikel 15.2 fest, wie die dem Dienst dienenden Erzeuger zu addieren sind: Eine Aufteilung der Anlage auf mehrere Maschinen erlaubt es nicht, jedes Typenschild isoliert zu betrachten.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">El RSIF utiliza otra magnitud para determinados l\u00edmites: la potencia el\u00e9ctrica instalada en los compresores, por sistema y para el conjunto de la instalaci\u00f3n. Los 30 y 100 kW del RSIF no son potencias t\u00e9rmicas, ni representan necesariamente la potencia el\u00e9ctrica total de la m\u00e1quina.<\/span><span class=\"une-t\" lang=\"en\">For certain limits, the RSIF uses a different quantity: the electrical power installed in the compressors, per system and for the installation as a whole. The RSIF thresholds of 30 and 100 kW are not thermal capacities and do not necessarily represent the total electrical power of the machine.<\/span><span class=\"une-t\" lang=\"fr\">Pour certaines limites, le RSIF utilise une autre grandeur : la puissance \u00e9lectrique install\u00e9e dans les compresseurs, par syst\u00e8me et pour l\u2019ensemble de l\u2019installation. Les seuils de 30 et 100 kW du RSIF ne sont pas des puissances thermiques et ne repr\u00e9sentent pas necessairement la puissance \u00e9lectrique totale de la machine.<\/span><span class=\"une-t\" lang=\"it\">Per determinati limiti, il RSIF utilizza un\u2019altra grandezza: la potenza elettrica installata nei compressori, per sistema e per l\u2019intero impianto. I 30 e 100 kW del RSIF non sono potenze termiche e non rappresentano necessariamente la potenza elettrica totale della macchina.<\/span><span class=\"une-t\" lang=\"de\">Fuer bestimmte Grenzwerte verwendet das RSIF eine andere Gr\u00f6\u00dfe: die installierte elektrische Leistung der Verdichter, je System und f\u00fcr die Gesamtanlage. Die 30 und 100 kW des RSIF sind keine Waermeleistungen und stellen nicht notwendigerweise die gesamte elektrische Leistung der Maschine dar.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">Ventiladores, bombas y resistencias no se incorporan indiscriminadamente a ese c\u00f3mputo. Tampoco procede sustituir la potencia instalada de compresi\u00f3n por una lectura instant\u00e1nea de consumo.<\/span><span class=\"une-t\" lang=\"en\">Fans, pumps and heaters are not indiscriminately included in that calculation. Nor should the installed compressor power be replaced by an instantaneous consumption reading.<\/span><span class=\"une-t\" lang=\"fr\">Les ventilateurs, pompes et r\u00e9sistances ne sont pas inclus indistinctement dans ce calcul. Il ne convient pas non plus de remplacer la puissance install\u00e9e des compresseurs par une mesure instantan\u00e9e de consommation.<\/span><span class=\"une-t\" lang=\"it\">Ventilatori, pompe e resistenze non vanno inclusi indiscriminatamente in tale calcolo. non \u00e8 neppure corretto sostituire la potenza installata dei compressori con una lettura istantanea del consumo.<\/span><span class=\"une-t\" lang=\"de\">Ventilatoren, Pumpen und Widerst\u00e4nde werden nicht unterschiedslos in diese Berechnung einbezogen. Ebenso wenig darf die installierte Verdichterleistung durch einen momentanen Verbrauchsmesswert ersetzt werden.<\/span><\/p>\r\n<\/div><div class=\"une-column\">\r\n<h2 class=\"rite-block-heading\"><span class=\"une-t\" lang=\"es\">Primer bloque: instalaciones de menos de 70 kW t\u00e9rmicos que s\u00ed necesitan proyecto por el RSIF<\/span><span class=\"une-t\" lang=\"en\">First group: installations below 70 kW thermal that still require an RSIF project<\/span><span class=\"une-t\" lang=\"fr\">Premier bloc : installations de moins de 70 kW thermiques qui n\u00e9cessitent tout de m\u00eame un projet au titre du RSIF<\/span><span class=\"une-t\" lang=\"it\">Primo blocco: impianti sotto i 70 kW termici che richiedono comunque un progetto ai sensi del RSIF<\/span><span class=\"une-t\" lang=\"de\">Erster Block: Anlagen unter 70 kW thermischer Leistung, f\u00fcr die das RSIF dennoch ein Projekt verlangt<\/span><\/h2>\r\n<p><span class=\"une-t\" lang=\"es\"><strong>Refrigerantes L3, como R290, cuando corresponde el r\u00e9gimen general de nivel 2.<\/strong> Una instalaci\u00f3n con propano puede exigir proyecto aunque entregue solamente 15, 30 o 60 kW t\u00e9rmicos. El motivo ser\u00e1 su encuadramiento reglamentario, no la proximidad al umbral del RITE.<\/span><span class=\"une-t\" lang=\"en\"><strong>L3 refrigerants such as R290, where the general level 2 regime applies.<\/strong> A propane installation may require a project even if it delivers only 15, 30 or 60 kW of thermal output. The reason is its regulatory classification, not its proximity to the RITE threshold.<\/span><span class=\"une-t\" lang=\"fr\"><strong>Fluides L3, comme le R290, lorsque le r\u00e9gime general de niveau 2 s\u2019appliqu\u00e9.<\/strong> Une installation au propane peut exiger un projet m\u00eame si elle ne fournit que 15, 30 ou 60 kW thermiques. La raison tient \u00e0 son classement r\u00e9glementaire, et non \u00e0 sa proximit\u00e9 du seuil du RITE.<\/span><span class=\"une-t\" lang=\"it\"><strong>Refrigeranti L3, come R290, quando si applica il regime generale di livello 2.<\/strong>Un impianto a propano pu\u00f2 richiedere un progetto anche se eroga soltanto 15, 30 o 60 kW termici. il motivo \u00e8 il suo inquadramento regolamentare, non la vicinanza alla soglia del RITE.<\/span><span class=\"une-t\" lang=\"de\"><strong>L3-K\u00e4ltemittel wie R290, wenn das allgemeine Regime der Stufe 2 gilt.<\/strong>Eine Propananlage kann ein Projekt erfordern, selbst wenn sie nur 15, 30 oder 60 kW W\u00e4rmeleistung erbringt. Entscheidend ist ihre regelungsrechtliche Einstufung, nicht die N\u00e4he zum RITE-Grenzwert.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">Aqu\u00ed entran, por ejemplo, los montajes cuyo circuito frigor\u00edfico se construye o interconecta en obra y que no pueden acogerse a la IF-20, siempre que tampoco resulte aplicable el tratamiento espec\u00edfico por peque\u00f1a carga del art\u00edculo 2.<\/span><span class=\"une-t\" lang=\"en\">This includes, for example, installations whose refrigeration circuit is built or interconnected on site and which cannot benefit from IF-20, provided that the specific treatment for small charges under Article 2 does not apply either.<\/span><span class=\"une-t\" lang=\"fr\">Cela comprend, par exemple, les montages dont le circuit frigorifique est construit ou interconnect\u00e9 sur site et qui ne peuvent relever de l\u2019IF-20, \u00e0 condition que le r\u00e9gime sp\u00e9cifique des petites charges de l\u2019article 2 ne soit pas non plus applicable.<\/span><span class=\"une-t\" lang=\"it\">Rientrano in questa categoria, ad esempio, i montaggi il cui circuito frigorifero viene costruito o interconnesso in cantiere e che non possono beneficiare della IF-20, sempre che non si applichi neppure il trattamento specifico per piccole cariche previsto dall\u2019articolo 2.<\/span><span class=\"une-t\" lang=\"de\">Dazu geh\u00f6ren beispielsweise Anlagen, deren K\u00e4ltekreislauf vor Ort errichtet oder verbunden wird und die IF-20 nicht in Anspruch nehmen k\u00f6nnen, sofern auch die Sonderregelung f\u00fcr kleine F\u00fcllmengen nach Artikel 2 nicht anwendbar ist.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">R290 no significa proyecto en todos los casos. Antes de exigirlo hay que comprobar el \u00e1mbito de aplicaci\u00f3n, la configuraci\u00f3n del sistema y las condiciones de la IF-20. Pero tampoco sirve la afirmaci\u00f3n inversa: una m\u00e1quina peque\u00f1a con propano no queda autom\u00e1ticamente cubierta por la memoria RITE.<\/span><span class=\"une-t\" lang=\"en\">R290 does not mean that a project is required in every case. Before requiring one, the scope of application, system configuration and IF-20 conditions must be checked. But the opposite statement is also incorrect: a small propane machine is not automatically covered by the RITE memorandum.<\/span><span class=\"une-t\" lang=\"fr\">Le R290 n\u2019implique pas un projet dans tous les cas. Avant de l\u2019exiger, il faut v\u00e9rifier le champ d\u2019application, la configuration du syst\u00e8me et les conditions de l\u2019IF-20. Mais l\u2019affirmation inverse est egalement fausse : une petite machine au propane n\u2019est pas automatiquement couverte par la m\u00e9moire RITE.<\/span><span class=\"une-t\" lang=\"it\">R290 non significa progetto in tutti i casi. Prima di richiederlo occorre verificare il campo di applicazione, la configurazione del sistema e le condizioni della IF-20. Ma non \u00e8 corretta neppure l\u2019affermazione opposta: una piccola macchina a propano non \u00e8 automaticamente coperta dalla memoria RITE.<\/span><span class=\"une-t\" lang=\"de\">R290 bedeutet nicht in jedem Fall, dass ein Projekt erforderlich ist. Vor einer solchen Forderung m\u00fcssen Anwendungsbereich, Systemkonfiguration und die Bedingungen der IF-20 gepr\u00fcft werden. Aber auch die umgekehrte Aussage ist falsch: Eine kleine Propananlage f\u00e4llt nicht automatisch unter die RITE-Dokumentation.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\"><strong>Refrigerantes L2 distintos de A2L, fuera de las excepciones aplicables.<\/strong> La simplificaci\u00f3n documental prevista para A2L no se extiende a todo el grupo L2.<\/span><span class=\"une-t\" lang=\"en\"><strong>L2 refrigerants other than A2L, outside the applicable exceptions.<\/strong> The simplified documentation route provided for A2L does not extend to the entire L2 group.<\/span><span class=\"une-t\" lang=\"fr\"><strong>Fluides L2 autres que A2L, hors des exceptions applicables.<\/strong> La simplification documentaire prevue pour les A2L ne s\u2019etend pas \u00e0 l\u2019ensemble du groupe L2.<\/span><span class=\"une-t\" lang=\"it\"><strong>Refrigeranti L2 diversi da A2L, al di fuori delle eccezioni applicabili.<\/strong> La semplificazione documentale prevista per gli A2L non si estende all\u2019intero gruppo L2.<\/span><span class=\"une-t\" lang=\"de\"><strong>Andere L2-K\u00e4ltemittel als A2L, au\u00dferhalb der anwendbaren Ausnahmen.<\/strong> Die f\u00fcr A2L vorgesehene vereinfachte Dokumentation gilt nicht f\u00fcr die gesamte L2-Gruppe.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">Si una instalaci\u00f3n destinada a servicios RITE utiliza este refrigerante y queda dentro del r\u00e9gimen general de nivel 2, necesita proyecto frigor\u00edfico.<\/span><span class=\"une-t\" lang=\"en\">If an installation intended for RITE services uses this refrigerant and falls under the general level 2 regime, it requires a refrigeration project.<\/span><span class=\"une-t\" lang=\"fr\">Si une installation destinee aux services relevant du RITE utilise ce refrigerant et releve du r\u00e9gime general de niveau 2, elle n\u00e9cessite un projet frigorifique.<\/span><span class=\"une-t\" lang=\"it\">Se un impianto destinato ai servizi RITE utilizza questo refrigerante e rientra nel regime generale di livello 2, necessita di un progetto frigorifero.<\/span><span class=\"une-t\" lang=\"de\">Wenn eine Anlage f\u00fcr RITE-Dienste dieses K\u00e4ltemittel verwendet und unter das allgemeine Regime der Stufe 2 f\u00e4llt, ist ein Kaelteanlagenprojekt erforderlich.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">Si una instalaci\u00f3n destinada a servicios RITE utiliza este refrigerante y queda dentro del r\u00e9gimen general de nivel 2, necesita proyecto frigor\u00edfico. Deben comprobarse previamente las posibles condiciones especiales de los sistemas indirectos compactos. La gu\u00eda ministerial aborda expresamente las instalaciones para confort inferiores a 70 kW y confirma la exigencia de proyecto para el nivel 2 ordinario.<\/span><span class=\"une-t\" lang=\"en\">If an installation intended for RITE services uses this refrigerant and falls under the general level 2 regime, it requires a refrigeration project. Any special conditions for compact indirect systems must first be checked. The ministerial guide expressly addresses comfort installations below 70 kW and confirms the project requirement for ordinary level 2.<\/span><span class=\"une-t\" lang=\"fr\">Si une installation destinee aux services relevant du RITE utilise ce refrigerant et releve du r\u00e9gime general de niveau 2, elle n\u00e9cessite un projet frigorifique. Il faut v\u00e9rifier au pr\u00e9alable les eventuelles conditions particulieres applicables aux systemes indirects compacts. Le guide ministeriel traite expressement des installations de confort de moins de 70 kW et confirme l\u2019exigence de projet pour le niveau 2 ordinaire.<\/span><span class=\"une-t\" lang=\"it\">Se un impianto destinato ai servizi RITE utilizza questo refrigerante e rientra nel regime generale di livello 2, necessita di un progetto frigorifero. Occorre prima verificare le eventuali condizioni speciali dei sistemi indiretti compatti. La guida ministeriale tratta espressamente gli impianti per il comfort inferiori a 70 kW e conferma l\u2019obbligo di progetto per il livello 2 ordinario.<\/span><span class=\"une-t\" lang=\"de\">Wenn eine Anlage f\u00fcr RITE-Dienste dieses K\u00e4ltemittel verwendet und unter das allgemeine Regime der Stufe 2 f\u00e4llt, ist ein Kaelteanlagenprojekt erforderlich. Zuvor m\u00fcssen moegliche Sonderbedingungen f\u00fcr kompakte indirekte Systeme gepr\u00fcft werden. Der Leitfaden des Ministeriums behandelt ausdruecklich Komfortanlagen unter 70 kW und bestaetigt die Projektpflicht f\u00fcr die regulaere Stufe 2.<\/span><\/p>\r\n<\/div><\/section>\r\n<section class=\"une-page-group une-page-group--separated\"><div class=\"une-column\">\r\n<p><span class=\"une-t\" lang=\"es\"><strong>Instalaciones que pasan a nivel 2 por potencia el\u00e9ctrica de compresi\u00f3n.<\/strong> Incluso utilizando un refrigerante L1 puede resultar obligatorio el proyecto cuando alg\u00fan sistema supera 30 kW el\u00e9ctricos instalados en sus compresores o el conjunto supera 100 kW, salvo que opere una excepci\u00f3n de clasificaci\u00f3n.<\/span><span class=\"une-t\" lang=\"en\"><strong>Installations classified as level 2 because of compressor electrical power.<\/strong> Even when using an L1 refrigerant, a project may be mandatory when any system exceeds 30 kW of electrical power installed in its compressors or the total exceeds 100 kW, unless a classification exception applies.<\/span><span class=\"une-t\" lang=\"fr\"><strong>Installations qui passent au niveau 2 en raison de la puissance \u00e9lectrique des compresseurs.<\/strong> Meme avec un refrigerant L1, un projet peut \u00eatre obligatoire lorsqu\u2019un syst\u00e8me d\u00e9passe 30 kW \u00e9lectriques installes dans ses compresseurs ou que l\u2019ensemble d\u00e9passe 100 kW, sauf exception de classement.<\/span><span class=\"une-t\" lang=\"it\"><strong>Impianti che passano al livello 2 per la potenza elettrica dei compressori.<\/strong> Anche utilizzando un refrigerante L1, il progetto pu\u00f2 essere obbligatorio quando un sistema supera 30 kW elettrici installati nei compressori o l\u2019insieme supera 100 kW, salvo che si applichi un\u2019eccezione di classificazione.<\/span><span class=\"une-t\" lang=\"de\"><strong>Anlagen, die aufgrund der elektrischen Verdichterleistung in Stufe 2 fallen.<\/strong>Auch bei Verwendung eines L1-Kaeltemittels kann ein Projekt vorgeschrieben sein, wenn ein System mehr als 30 kW installierte elektrische Verdichterleistung aufweist oder die Gesamtanlage 100 kW \u00fcberschreitet, sofern keine Einstufungsausnahme greift.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">Ahora bien, el art\u00edculo 8 contempla determinados equipos compactos L1 con condensador incorporado, incluidas enfriadoras y bombas de calor, como nivel 1 con independencia de su potencia. Por eso tampoco ser\u00eda correcto publicar una regla que dijera simplemente \u00abm\u00e1s de 30 kW el\u00e9ctricos: proyecto\u00bb.<\/span><span class=\"une-t\" lang=\"en\">However, Article 8 classifies certain compact L1 units with an integral condenser, including chillers and heat pumps, as level 1 regardless of their power. It would therefore also be incorrect to publish a rule stating simply \u201cmore than 30 kW electrical: project\u201d.<\/span><span class=\"une-t\" lang=\"fr\">Toutefois, l\u2019article 8 classe certains appareils compacts L1 avec condenseur integre, notamment les refroidisseurs et les pompes \u00e0 chaleur, au niveau 1 quelle que soit leur puissance. Il serait donc egalement incorrect d\u2019enoncer simplement : \u00ab plus de 30 kW \u00e9lectriques : projet \u00bb.<\/span><span class=\"une-t\" lang=\"it\">L\u2019articolo 8 considera pero determinati apparecchi compatti L1 con condensatore incorporato, comprese le unit\u00e0 refrigeratrici e le pompe di calore, come livello 1 indipendentemente dalla potenza. Sarebbe quindi errato anche formulare una regola del tipo \u00aboltre 30 kW elettrici: progetto\u00bb.<\/span><span class=\"une-t\" lang=\"de\">Artikel 8 stuft jedoch bestimmte kompakte L1-Ger\u00e4te mit eingebautem Verfl\u00fcssiger, darunter Kaltwassersaetze und W\u00e4rmepumpen, unabhaengig von ihrer Leistung als Stufe 1 ein. Daher w\u00e4re auch die pauschale Aussage \u201emehr als 30 kW elektrisch: Projekt\u201c falsch.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\"><strong>Instalaciones A2L que quedan fuera del r\u00e9gimen documental simplificado por sus caracter\u00edsticas.<\/strong> R32 y otros A2L no disfrutan de una exenci\u00f3n universal de proyecto. Cuando la instalaci\u00f3n supera los l\u00edmites de potencia de compresi\u00f3n que permiten la v\u00eda simplificada y no puede acogerse a otra excepci\u00f3n, corresponde el r\u00e9gimen general de nivel 2: proyecto y direcci\u00f3n t\u00e9cnica. Para aplicar esa v\u00eda deben comprobarse conjuntamente los l\u00edmites de 30 kW por sistema y 100 kW para el conjunto, como recoge expresamente el art\u00edculo 21.4 y explica la gu\u00eda ministerial.<\/span><span class=\"une-t\" lang=\"en\"><strong>A2L installations that fall outside the simplified documentation route because of their characteristics.<\/strong> R32 and other A2L refrigerants do not benefit from a universal exemption from project requirements. When the installation exceeds the compressor-power limits that allow the simplified route and cannot benefit from another exception, the general level 2 regime applies: project and technical supervision. To apply this route, the limits of 30 kW per system and 100 kW for the installation as a whole must be checked together, as expressly set out in Article 21(4) and explained in the ministerial guide.<\/span><span class=\"une-t\" lang=\"fr\"><strong>Installations A2L exclues du r\u00e9gime documentaire simplifie en raison de leurs caract\u00e9ristiques.<\/strong> Le R32 et les autres r\u00e9frig\u00e9rants A2L ne beneficient pas d\u2019une exemption generale de projet. Lorsque l\u2019installation d\u00e9passe les limites de puissance des compresseurs permettant la voie simplifiee et ne peut relever d\u2019une autre exception, le r\u00e9gime general de niveau 2 s\u2019appliqu\u00e9 : projet et direction technique. Pour appliquer cette voie, il faut v\u00e9rifier conjointement les limites de 30 kW par syst\u00e8me et de 100 kW pour l\u2019ensemble, comme le pr\u00e9voit expressement l\u2019article 21.4 et l\u2019explique le guide ministeriel.<\/span><span class=\"une-t\" lang=\"it\"><strong>Impianti A2L esclusi dal regime documentale semplificato per le loro caratteristiche.<\/strong>R32 e gli altri refrigeranti A2L non beneficiano di un\u2019esenzione universale dal progetto. Quando l\u2019impianto supera i limiti di potenza dei compressori che consentono la procedura semplificata e non pu\u00f2 avvalersi di un\u2019altra eccezione, si applica il regime generale di livello 2: progetto e direzione tecnica. Per applicare tale procedura occorre verificare congiuntamente i limiti di 30 kW per sistema e 100 kW per l\u2019intero impianto, come previsto espressamente dall\u2019articolo 21.4 e spiegato dalla guida ministeriale.<\/span><span class=\"une-t\" lang=\"de\"><strong>A2L-Anlagen, die aufgrund ihrer Eigenschaften nicht unter das vereinfachte Dokumentationsverfahren fallen.<\/strong>R32 und andere A2L-K\u00e4ltemittel geniessen keine allgemeine Befreiung von der Projektpflicht. \u00dcberschreitet die Anlage die Verdichterleistungsgrenzen f\u00fcr das vereinfachte Verfahren und kann keine andere Ausnahme in Anspruch nehmen, gilt das allgemeine Regime der Stufe 2: Projekt und technische Leitung. Fuer dieses Verfahren m\u00fcssen die Grenzen von 30 kW je System und 100 kW f\u00fcr die Gesamtanlage gemeinsam gepr\u00fcft werden, wie Artikel 21.4 ausdruecklich vorsieht und der Leitfaden des Ministeriums erlaeutert.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">La carga necesita un an\u00e1lisis diferente. Superar un l\u00edmite de carga no permite concluir, por s\u00ed solo, que desaparece toda posibilidad de tramitar mediante memoria. Los apartados 3 y 4 del art\u00edculo 21 contemplan documentaci\u00f3n espec\u00edfica y participaci\u00f3n de t\u00e9cnicos y empresas de nivel 2.<\/span><span class=\"une-t\" lang=\"en\">The refrigerant charge requires a separate analysis. Exceeding a charge limit does not, by itself, mean that the possibility of filing a memorandum is ruled out. Paragraphs 3 and 4 of Article 21 provide for specific documentation and the involvement of technicians and level 2 companies.<\/span><span class=\"une-t\" lang=\"fr\">La charge n\u00e9cessite une analyse distincte. Le depassement d\u2019une limite de charge ne permet pas, \u00e0 lui seul, de conclure que toute procedure par m\u00e9moire est exclue. Les paragraphes 3 et 4 de l\u2019article 21 prevoient une documentation sp\u00e9cifique et l\u2019intervention de techniciens et d\u2019entreprises de niveau 2.<\/span><span class=\"une-t\" lang=\"it\">La carica richiede un\u2019analisi distinta. Il superamento di un limite di carica non consente, da solo, di concludere che venga meno ogni possibilit\u00e0 di procedere con una memoria. I paragrafi 3 e 4 dell\u2019articolo 21 prevedono documentazione specifica e la partecipazione di tecnici e imprese di livello 2.<\/span><span class=\"une-t\" lang=\"de\">Die F\u00fcllmenge erfordert eine gesonderte Analyse. Die Ueberschreitung eines Fuellmengengrenzwerts bedeutet f\u00fcr sich genommen nicht, dass eine Dokumentation ausgeschlossen ist. Die Absaetze 3 und 4 des Artikels 21 sehen eine besondere Dokumentation sowie die Beteiligung von Technikern und Unternehmen der Stufe 2 vor.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">Estas comprobaciones tambi\u00e9n alcanzan a las reformas. Una ampliaci\u00f3n, una modificaci\u00f3n del circuito o un cambio de refrigerante pueden alterar el r\u00e9gimen aplicable. La IF-15 obliga a valorar la instalaci\u00f3n resultante; la peque\u00f1a potencia del equipo a\u00f1adido no resuelve por s\u00ed sola la documentaci\u00f3n de la intervenci\u00f3n.<\/span><span class=\"une-t\" lang=\"en\">These checks also apply to modifications. An extension, a change to the circuit or a refrigerant change may alter the applicable regime. IF-15 requires the resulting installation to be assessed; the low power of the added unit does not, by itself, determine the documentation required for the work.<\/span><span class=\"une-t\" lang=\"fr\">Ces verifications s\u2019appliquent egalement aux modifications. Une extension, une modification du circuit ou un changement de refrigerant peuvent modifier le r\u00e9gime applicable. L\u2019IF-15 impose d\u2019evaluer l\u2019installation qui en resulte ; la faible puissance de l\u2019equipement ajoute ne determine pas, \u00e0 elle seule, les documents requis pour l\u2019intervention.<\/span><span class=\"une-t\" lang=\"it\">Queste verifiche riguardano anche le modifiche. Un ampliamento, una modifica del circuito o un cambio di refrigerante possono alterare il regime applicabile. La IF-15 impone di valutare l\u2019impianto risultante; la bassa potenza dell\u2019apparecchio aggiunto non determina, da sola, la documentazione richiesta per l\u2019intervento.<\/span><span class=\"une-t\" lang=\"de\">Diese Pruefungen gelten auch f\u00fcr Aenderungen. Eine Erweiterung, eine Aenderung des Kreislaufs oder ein Kaeltemittelwechsel k\u00f6nnen das anwendbare Regime veraendern. IF-15 verlangt eine Bewertung der resultierenden Anlage; die geringe Leistung des hinzugefuegten Geraets bestimmt nicht allein die f\u00fcr den Eingriff erforderlichen Unterlagen.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">La IF-20 explica por qu\u00e9 muchas bombas de calor con R290 pueden instalarse con memoria. Su planteamiento parte de un sistema indirecto cerrado cuyo refrigerante permanece en equipos compactos. Durante la instalaci\u00f3n, el instalador no modifica el circuito primario ni su carga.<\/span><span class=\"une-t\" lang=\"en\">IF-20 explains why many R290 heat pumps can be installed using a memorandum. It is based on a closed indirect system in which the refrigerant remains inside compact units. During installation, the installer does not modify the primary circuit or its charge.<\/span><span class=\"une-t\" lang=\"fr\">L\u2019IF-20 explique pourquoi de nombreuses pompes \u00e0 chaleur au R290 peuvent etre installees avec une m\u00e9moire. Elle repose sur un syst\u00e8me indirect ferme dont le refrigerant reste dans des appareils compacts. Pendant l\u2019installation, l\u2019installateur ne modifie ni le circuit primaire ni sa charge.<\/span><span class=\"une-t\" lang=\"it\">La IF-20 spiega perch\u00e9 molte pompe di calore con R290 possono essere installate con una memoria. Il suo approccio si basa su un sistema indiretto chiuso il cui refrigerante rimane in apparecchi compatti. Durante l\u2019installazione, l\u2019installatore non modifica il circuito primario ne la sua carica.<\/span><span class=\"une-t\" lang=\"de\">IF-20 erklaert, warum viele W\u00e4rmepumpen mit R290 mit einer Dokumentation installiert werden k\u00f6nnen. Ihr Ansatz beruht auf einem geschlossenen indirekten System, dessen K\u00e4ltemittel in kompakten Geraeten verbleibt. Bei der Installation veraendert der Installateur weder den Primaerkreislauf noch dessen F\u00fcllmenge.<\/span><\/p>\r\n<\/div><div class=\"une-column\">\r\n<h2 class=\"rite-block-heading\"><span class=\"une-t\" lang=\"es\">Segundo bloque: casos en que puede bastar una memoria, pero debe intervenir un t\u00e9cnico titulado competente.1.<\/span><span class=\"une-t\" lang=\"en\">Second group: cases where a memorandum may suffice, but a competent qualified technician must be involved.1.<\/span><span class=\"une-t\" lang=\"fr\">Deuxi\u00e8me bloc : cas o\u00f9 une m\u00e9moire peut suffire, mais o\u00f9 un technicien qualifi\u00e9 comp\u00e9tent doit intervenir.1.<\/span><span class=\"une-t\" lang=\"it\">Secondo blocco: casi in cui pu\u00f2 bastare una memoria, ma deve intervenire un tecnico abilitato competente.1.<\/span><span class=\"une-t\" lang=\"de\">Zweiter Block: F\u00e4lle, in denen eine Dokumentation ausreichen kann, aber ein qualifizierter fachkundiger Techniker mitwirken muss.1.<\/span><\/h2>\r\n<p><span class=\"une-t\" lang=\"es\"><strong>A2L que utiliza las disposiciones del ap\u00e9ndice 4 de la IF-04 para justificar su carga.<\/strong> Este es uno de los supuestos m\u00e1s relevantes en expansi\u00f3n directa para confort. La consulta 74 de la gu\u00eda t\u00e9cnica ministerial distingue la v\u00eda ordinaria del ap\u00e9ndice 3 de la alternativa del ap\u00e9ndice 4. Para esta \u00faltima identifica la intervenci\u00f3n del t\u00e9cnico titulado competente en la memoria, aunque la instalaci\u00f3n pueda ejecutarla una empresa de nivel 1 dentro de las condiciones correspondientes.<\/span><span class=\"une-t\" lang=\"en\"><strong>A2L using the provisions of Appendix 4 of IF-04 to justify its charge.<\/strong> This is one of the most relevant cases for direct-expansion comfort systems. Consultation 74 of the ministerial technical guide distinguishes the ordinary route under Appendix 3 from the alternative under Appendix 4. For the latter, it identifies the involvement of a competent qualified technician in the memorandum, even though the installation may be carried out by a level 1 company under the applicable conditions.<\/span><span class=\"une-t\" lang=\"fr\"><strong>A2L utilisant les dispositions de l\u2019appendice 4 de l\u2019IF-04 pour justifier sa charge.<\/strong> C\u2019est l\u2019un des cas les plus importants pour les systemes \u00e0 detente directe destines au confort. La consultation 74 du guide technique ministeriel distingue la voie ordinaire de l\u2019appendice 3 de l\u2019alternative de l\u2019appendice 4. Pour cette derniere, elle identifie l\u2019intervention du technicien qualifi\u00e9 comp\u00e9tent dans la m\u00e9moire, m\u00eame si l\u2019installation peut \u00eatre realisee par une entreprise de niveau 1 dans les conditions correspondantes.<\/span><span class=\"une-t\" lang=\"it\"><strong>A2L che utilizza le disposizioni dell\u2019appendice 4 della IF-04 per giustificare la propria carica.<\/strong> Questo e uno dei casi pi\u00f9 rilevanti per i sistemi a espansione diretta destinati al comfort. La consultazione 74 della guida tecnica ministeriale distingue la procedura ordinaria dell\u2019appendice 3 dall\u2019alternativa dell\u2019appendice 4. Per quest\u2019ultima individua l\u2019intervento del tecnico abilitato competente nella memoria, anche se l\u2019impianto pu\u00f2 essere eseguito da un\u2019impresa di livello 1 alle condizioni previste.<\/span><span class=\"une-t\" lang=\"de\"><strong>A2L, bei dem die Bestimmungen des Anhangs 4 der IF-04 zur Begr\u00fcndung der F\u00fcllmenge herangezogen werden.<\/strong>Dies ist einer der wichtigsten F\u00e4lle bei Direktverdampfungssystemen f\u00fcr Komfortanwendungen. Die Konsultation 74 des technischen Leitfadens des Ministeriums unterscheidet den regulaeren Weg nach Anhang 3 von der Alternative nach Anhang 4. Fuer Letztere sieht sie die Mitwirkung eines qualifizierten fachkundigen Technikers an der Dokumentation vor, auch wenn die Anlage unter den entsprechenden Bedingungen von einem Unternehmen der Stufe 1 ausgef\u00fchrt werden kann.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">Se trata de un criterio interpretativo oficial; la gu\u00eda no tiene car\u00e1cter vinculante. Su utilidad consiste en aclarar la aplicaci\u00f3n del art\u00edculo 21.3.a, que reserva al t\u00e9cnico el documento justificativo cuando concurren las circunstancias que especifica.<\/span><span class=\"une-t\" lang=\"en\">This is an official interpretative criterion; the guide is not legally binding. Its purpose is to clarify the application of Article 21(3)(a), which reserves the supporting document to the technician when the specified circumstances apply.<\/span><span class=\"une-t\" lang=\"fr\">Il s\u2019agit d\u2019un critere interpretatif officiel ; le guide n\u2019\u00e0 pas de caract\u00e8re contraignant. Il vise \u00e0 clarifier l\u2019application de l\u2019article 21.3.\u00e0, qui r\u00e9serve au technicien le document justificatif lorsque les circonstances qu\u2019il pr\u00e9cise sont r\u00e9unies.<\/span><span class=\"une-t\" lang=\"it\">Si tratta di un criterio interpretativo ufficiale; la guida non e vincolante. La sua utilita consiste nel chiarire l\u2019applicazione dell\u2019articolo 21.3.a, che riserva al tecnico il documento giustificativo quando ricorrono le circostanze specificate.<\/span><span class=\"une-t\" lang=\"de\">Es handelt sich um ein offizielles Auslegungskriterium; der Leitfaden ist nicht verbindlich. Er soll die Anwendung von Artikel 21.3.a erlaeutern, der das Nachweisdokument dem Techniker vorbeh\u00e4lt, wenn die dort genannten Umstaende vorliegen.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">El ap\u00e9ndice 4 tampoco ofrece una autorizaci\u00f3n gen\u00e9rica para aumentar cargas. Exige verificar su \u00e1mbito de aplicaci\u00f3n, los espacios afectados y las medidas de seguridad necesarias. Colocar un detector sin justificar el conjunto no completa ese trabajo.<\/span><span class=\"une-t\" lang=\"en\">Appendix 4 does not provide a general authorisation to increase charges either. Its scope of application, the spaces concerned and the necessary safety measures must be verified. Installing a detector without justifying the system as a whole does not complete that work.<\/span><span class=\"une-t\" lang=\"fr\">L\u2019appendice 4 n\u2019offre pas non plus une autorisation generale d\u2019augmenter les charges. Il faut v\u00e9rifier son champ d\u2019application, les espaces concernes et les mesures de s\u00e9curit\u00e9 n\u00e9cessaires. Installer un detecteur sans justifier l\u2019ensemble ne suffit pas.<\/span><span class=\"une-t\" lang=\"it\">L\u2019appendice 4 non offre neppure un\u2019autorizzazione generale ad aumentare le cariche. Occorre verificare il suo campo di applicazione, gli spazi interessati e le misure di sicurezza necessarie. Installare un rilevatore senza giustificare l\u2019insieme non completa il lavoro.<\/span><span class=\"une-t\" lang=\"de\">Anhang 4 bietet ebenfalls keine allgemeine Genehmigung zur Erhoehung von F\u00fcllmengen. Sein Anwendungsbereich, die betroffenen Raeume und die erforderlichen Sicherheitsmassnahmen m\u00fcssen gepr\u00fcft werden. Ein Detektor allein, ohne Begr\u00fcndung des Gesamtsystems, reicht dafuer nicht aus.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\"><strong>A2L cuando resulta obligatorio el an\u00e1lisis de riesgos previsto en el art\u00edculo 21.3.<\/strong> Si la situaci\u00f3n exige ese an\u00e1lisis o supera los l\u00edmites contemplados para la justificaci\u00f3n ordinaria, el t\u00e9cnico competente debe asumir la documentaci\u00f3n que le corresponde.<\/span><span class=\"une-t\" lang=\"en\"><strong>A2L cases in which the risk analysis provided for in Article 21(3) is mandatory.<\/strong> If the situation requires that analysis or exceeds the limits provided for ordinary justification, the competent technician must take responsibility for the documentation required of them.<\/span><span class=\"une-t\" lang=\"fr\"><strong>A2L lorsque l\u2019analyse des risques prevue \u00e0 l\u2019article 21.3 est obligatoire.<\/strong> Si la situation exige cette analyse ou d\u00e9passe les limites pr\u00e9vues pour la justification ordinaire, le technicien comp\u00e9tent doit prendre en charge la documentation qui lui incombe.<\/span><span class=\"une-t\" lang=\"it\"><strong>A2L quando e obbligatoria l\u2019analisi dei rischi prevista dall\u2019articolo 21.3.<\/strong> Se la situazione richiede tale analisi o supera i limiti previsti per la giustificazione ordinaria, il tecnico competente deve assumere la documentazione di propria competenza.<\/span><span class=\"une-t\" lang=\"de\"><strong>A2L-F\u00e4lle, in denen die in Artikel 21.3 vorgesehene Risikoanalyse vorgeschrieben ist.<\/strong>Wenn die Situation diese Analyse erfordert oder die f\u00fcr die regulaere Begr\u00fcndung vorgesehenen Grenzen \u00fcberschreitet, muss der zust\u00e4ndige Techniker die ihm obliegende Dokumentation verantworten.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">El art\u00edculo 21.3.b exige adem\u00e1s una empresa instaladora de nivel 2 para el supuesto que regula. Pero el apartado 4 permite a instalaciones A2L que cumplen sus condiciones de potencia y uso presentar la documentaci\u00f3n del apartado 3 como alternativa a la documentaci\u00f3n general de nivel 2. Por tanto, puede existir una combinaci\u00f3n perfectamente reglamentaria de memoria, c\u00e1lculo justificativo y an\u00e1lisis de riesgos firmados por t\u00e9cnico competente, con ejecuci\u00f3n por empresa de nivel 2. La intervenci\u00f3n de esa empresa no convierte autom\u00e1ticamente la memoria en proyecto.<\/span><span class=\"une-t\" lang=\"en\">Article 21(3)(b) also requires a level 2 installation company for the case it regulates. However, paragraph 4 allows A2L installations that meet its power and use conditions to submit the documentation under paragraph 3 as an alternative to the general level 2 documentation. Therefore, a fully compliant combination may consist of a memorandum, supporting calculation and risk analysis signed by a competent technician, with the work carried out by a level 2 company. The involvement of that company does not automatically turn the memorandum into a project.<\/span><span class=\"une-t\" lang=\"fr\">L\u2019article 21.3.b exige egalement une entreprise d\u2019installation de niveau 2 pour le cas qu\u2019il regit. Toutefois, le paragraphe 4 permet aux installations A2L qui respectent ses conditions de puissance et d\u2019usage de presenter la documentation du paragraphe 3 en remplacement de la documentation generale de niveau 2. Il peut donc exister une combinaison parfaitement conforme comprenant une m\u00e9moire, un calcul justificatif et une analyse des risques signes par un technicien comp\u00e9tent, avec une ex\u00e9cution par une entreprise de niveau 2. L\u2019intervention de cette entreprise ne transforme pas automatiquement la m\u00e9moire en projet.<\/span><span class=\"une-t\" lang=\"it\">L\u2019articolo 21.3.b richiede inoltre un\u2019impresa installatrice di livello 2 per il caso disciplinato. Tuttavia, il paragrafo 4 consente agli impianti A2L che rispettano le condizioni di potenza e di utilizzo di presentare la documentazione del paragrafo 3 in alternativa alla documentazione generale di livello 2. pu\u00f2 quindi esistere una combinazione pienamente conforme di memoria, calcolo giustificativo e analisi dei rischi firmati da un tecnico competente, con esecuzione da parte di un\u2019impresa di livello 2. L\u2019intervento di tale impresa non trasforma automaticamente la memoria in progetto.<\/span><span class=\"une-t\" lang=\"de\">Artikel 21.3.b verlangt f\u00fcr den dort geregelten Fall au\u00dferdem ein Installationsunternehmen der Stufe 2. Absatz 4 erlaubt jedoch A2L-Anlagen, die seine Leistungs- und Nutzungsbedingungen erfuellen, die Unterlagen nach Absatz 3 als Alternative zur allgemeinen Dokumentation der Stufe 2 vorzulegen. Somit kann eine regelkonforme Kombination aus Dokumentation, Begr\u00fcndungsberechnung und Risikoanalyse bestehen, die von einem zust\u00e4ndigen Techniker unterzeichnet wird, w\u00e4hrend die Ausf\u00fchrung durch ein Unternehmen der Stufe 2 erfolgt. Die Mitwirkung dieses Unternehmens macht aus der Dokumentation nicht automatisch ein Projekt.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">Eso no autoriza cargas arbitrarias. El an\u00e1lisis debe demostrar una soluci\u00f3n admisible. Si el dise\u00f1o recurre a una soluci\u00f3n alternativa al reglamento, el art\u00edculo 19.1.b exige el informe favorable de un organismo de control y la aprobaci\u00f3n auton\u00f3mica antes de ejecutar.<\/span><span class=\"une-t\" lang=\"en\">This does not authorise arbitrary charges. The analysis must demonstrate an admissible solution. If the design uses a solution that is an alternative to the regulations, Article 19(1)(b) requires a favourable report from a control body and regional approval before implementation.<\/span><span class=\"une-t\" lang=\"fr\">Cela n\u2019autorise pas des charges arbitraires. L\u2019analyse doit demontrer une solution admissible. Si la conception recourt \u00e0 une solution alternative au r\u00e8glement, l\u2019article 19.1.b exige un rapport favorable d\u2019un organisme de controle et l\u2019approbation de la communaut\u00e9 autonome avant l\u2019ex\u00e9cution.<\/span><span class=\"une-t\" lang=\"it\">Questo non autorizza cariche arbitrarie. L\u2019analisi deve dimostrare una soluzione ammissibile. Se il progetto ricorre a una soluzione alternativa al regolamento, l\u2019articolo 19.1.b richiede il parere favorevole di un organismo di controllo e l\u2019approvazione regionale prima dell\u2019esecuzione.<\/span><span class=\"une-t\" lang=\"de\">Dies erlaubt keine beliebigen F\u00fcllmengen. Die Analyse muss eine zul\u00e4ssige Loesung nachweisen. Verwendet die Planung eine vom Regelwerk abweichende Loesung, verlangt Artikel 19.1.b vor der Ausf\u00fchrung einen positiven Bericht einer Kontrollstelle und die Genehmigung der autonomen Gemeinschaft.<\/span><\/p>\r\n<\/div><\/section>\r\n<section class=\"une-page-group une-page-group--separated\"><div class=\"une-column\">\r\n<p><span class=\"une-t\" lang=\"es\"><strong>La responsabilidad t\u00e9cnica de la empresa constituye una obligaci\u00f3n distinta.<\/strong> Una empresa de nivel 2 debe disponer del personal t\u00e9cnico que exige el art\u00edculo 12. Esta responsabilidad empresarial no equivale, sin m\u00e1s, a redactar un proyecto para cada actuaci\u00f3n.<\/span><span class=\"une-t\" lang=\"en\"><strong>The company\u2019s technical responsibility is a separate obligation.<\/strong> A level 2 company must have the technical staff required by Article 12. This corporate responsibility does not, by itself, mean that a project must be drawn up for every intervention.<\/span><span class=\"une-t\" lang=\"fr\"><strong>La responsabilite technique de l\u2019entreprise constitue une obligation distincte.<\/strong> Une entreprise de niveau 2 doit disposer du personnel technique exige par l\u2019article 12. Cette responsabilite de l\u2019entreprise n\u2019equivaut pas, \u00e0 elle seule, \u00e0 l\u2019obligation de rediger un projet pour chaque intervention.<\/span><span class=\"une-t\" lang=\"it\"><strong>La responsabilita tecnica dell\u2019impresa costituisce un obbligo distinto.<\/strong> Un\u2019impresa di livello 2 deve disporre del personale tecnico richiesto dall\u2019articolo 12. Questa responsabilita aziendale non equivale, di per se, alla redazione di un progetto per ogni intervento.<\/span><span class=\"une-t\" lang=\"de\"><strong>Die technische Verantwortung des Unternehmens ist eine eigenst\u00e4ndige Pflicht.<\/strong>Ein Unternehmen der Stufe 2 muss \u00fcber das in Artikel 12 vorgeschriebene technische Personal verfuegen. Diese Unternehmensverantwortung bedeutet nicht ohne Weiteres, dass f\u00fcr jeden Eingriff ein Projekt erstellt werden muss.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">La distinci\u00f3n resulta especialmente \u00fatil en la IF-20: el tratamiento de la instalaci\u00f3n permite memoria, mientras que el mantenimiento del circuito primario exige las empresas previstas en su apartado 4.2. De ah\u00ed no nace una obligaci\u00f3n general de que la propiedad contrate un proyecto retrospectivo. Conviene separar autor de la memoria, responsable t\u00e9cnico de la empresa y director de la instalaci\u00f3n: son funciones diferentes.<\/span><span class=\"une-t\" lang=\"en\">The distinction is particularly useful under IF-20: the installation procedure allows a memorandum, while maintenance of the primary circuit requires the companies provided for in section 4.2. This does not create a general obligation for the owner to commission a retrospective project. The author of the memorandum, the company\u2019s technical manager and the installation director should be distinguished: they are different roles.<\/span><span class=\"une-t\" lang=\"fr\">Cette distinction est particulierement utile pour l\u2019IF-20 : le traitement de l\u2019installation permet une m\u00e9moire, tandis que la maintenance du circuit primaire exige les entreprises pr\u00e9vues \u00e0 son paragraphe 4.2. Il n\u2019en resulte pas une obligation generale pour le proprietaire de commander un projet \u00e0 posteriori. Il convient de distinguer l\u2019auteur de la m\u00e9moire, le responsable technique de l\u2019entreprise et le directeur de l\u2019installation : ce sont des fonctions differentes.<\/span><span class=\"une-t\" lang=\"it\">La distinzione e particolarmente utile nella IF-20: il trattamento dell\u2019installazione consente una memoria, mentre la manutenzione del circuito primario richiede le imprese previste al punto 4.2. Da cio non deriva un obbligo generale per la propriet\u00e0 di commissionare un progetto retrospettivo. Occorre distinguere l\u2019autore della memoria, il responsabile tecnico dell\u2019impresa e il direttore dell\u2019impianto: sono funzioni diverse.<\/span><span class=\"une-t\" lang=\"de\">Diese Unterscheidung ist bei IF-20 besonders nuetzlich: Das Verfahren f\u00fcr die Installation erlaubt eine Dokumentation, w\u00e4hrend die Wartung des Primaerkreislaufs die in Abschnitt 4.2 vorgesehenen Unternehmen erfordert. Daraus entsteht keine allgemeine Pflicht des Eigentuemers, nachtraeglich ein Projekt in Auftrag zu geben. Verfasser der Dokumentation, technischer Verantwortlicher des Unternehmens und Anlagenleiter sind unterschiedliche Funktionen.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">Un VRF con R32 permite ver d\u00f3nde aparece realmente el problema. Supongamos una instalaci\u00f3n de 50 kW t\u00e9rmicos que cumple los l\u00edmites de potencia de compresi\u00f3n. La carga final depender\u00e1 de la configuraci\u00f3n y de las tuber\u00edas ejecutadas.<\/span><span class=\"une-t\" lang=\"en\">An R32 VRF system shows where the problem actually arises. Suppose an installation has 50 kW of thermal capacity and meets the compressor power limits. The final charge will depend on the configuration and the pipework installed.<\/span><span class=\"une-t\" lang=\"fr\">Un syst\u00e8me VRF au R32 permet de voir ou se situe reellement le probl\u00e8me. Supposons une installation de 50 kW thermiques qui respecte les limites de puissance des compresseurs. La charge finale dependra de la configuration et des tuyauteries installees.<\/span><span class=\"une-t\" lang=\"it\">Un sistema VRF con R32 permette di vedere dove si presenta realmente il problema. Supponiamo un impianto da 50 kW termici che rispetta i limiti di potenza dei compressori. La carica finale dipendera dalla configurazione e dalle tubazioni realizzate.<\/span><span class=\"une-t\" lang=\"de\">Ein VRF-System mit R32 zeigt, wo das eigentliche Problem liegt. Angenommen, eine Anlage hat 50 kW W\u00e4rmeleistung und haelt die Verdichterleistungsgrenzen ein. Die endgueltige F\u00fcllmenge h\u00e4ngt von der Konfiguration und den ausgef\u00fchrten Rohrleitungen ab.<\/span><\/p>\r\n<\/div><div class=\"une-column\">\r\n<p><span class=\"une-t\" lang=\"es\">A\u00f1adir la cantidad de refrigerante que prescribe el fabricante no obliga, por ese solo hecho, a presentar proyecto ni a contratar un t\u00e9cnico para cualquier montaje. Obliga a utilizar la carga final correcta en la comprobaci\u00f3n de seguridad.<\/span><span class=\"une-t\" lang=\"en\">Adding the quantity of refrigerant prescribed by the manufacturer does not, by itself, require a project or the engagement of a technician for every installation. It requires the correct final charge to be used in the safety assessment.<\/span><span class=\"une-t\" lang=\"fr\">Ajouter la quantite de refrigerant prescrite par le fabricant n\u2019oblige pas, \u00e0 elle seule, \u00e0 presenter un projet ni \u00e0 faire appel \u00e0 un technicien pour chaque montage. Cela impose d\u2019utiliser la charge finale correcte dans la v\u00e9rification de s\u00e9curit\u00e9.<\/span><span class=\"une-t\" lang=\"it\">Aggiungere la quantita di refrigerante prescritta dal fabbricante non obbliga, per questo solo fatto, a presentare un progetto ne a incaricare un tecnico per ogni montaggio. Impone di utilizzare la carica finale corretta nella verifica di sicurezza.<\/span><span class=\"une-t\" lang=\"de\">Die vom Hersteller vorgeschriebene Kaeltemittelmenge hinzuzufuegen, verpflichtet f\u00fcr sich genommen weder zur Vorlage eines Projekts noch dazu, bei jeder Montage einen Techniker zu beauftragen. Bei der Sicherheitspruefung muss jedoch die korrekte endgueltige F\u00fcllmenge zugrunde gelegt werden.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">El resultado puede cambiar al atender un despacho peque\u00f1o, modificar la distribuci\u00f3n o incorporar una unidad interior. Una instalaci\u00f3n que cumple las condiciones de la justificaci\u00f3n ordinaria puede pasar a necesitar medidas del ap\u00e9ndice 4 y la intervenci\u00f3n t\u00e9cnica correspondiente.<\/span><span class=\"une-t\" lang=\"en\">The result may change when serving a small office, modifying the layout or adding an indoor unit. An installation that meets the conditions for ordinary justification may come to require the measures in Appendix 4 and the corresponding technical involvement.<\/span><span class=\"une-t\" lang=\"fr\">Le resultat peut changer lorsqu\u2019on dessert un petit bureau, que l\u2019on modifie la distribution ou que l\u2019on ajoute une unite int\u00e9rieure. Une installation qui satisfait aux conditions de la justification ordinaire peut alors n\u00e9cessiter les mesures de l\u2019appendice 4 et l\u2019intervention technique correspondante.<\/span><span class=\"une-t\" lang=\"it\">Il risultato pu\u00f2 cambiare servendo un piccolo ufficio, modificando la distribuzione o aggiungendo un\u2019unit\u00e0 interna. Un impianto che soddisfa le condizioni della giustificazione ordinaria pu\u00f2 arrivare a richiedere le misure dell\u2019appendice 4 e il relativo intervento tecnico.<\/span><span class=\"une-t\" lang=\"de\">Das Ergebnis kann sich aendern, wenn ein kleines Buero versorgt, die Raumaufteilung geaendert oder ein Innengeraet hinzugefuegt wird. Eine Anlage, die die Bedingungen der regulaeren Begr\u00fcndung erfuellt, kann dann Massnahmen nach Anhang 4 und die entsprechende technische Mitwirkung erfordern.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">Por eso resulta insuficiente archivar \u00fanicamente la selecci\u00f3n comercial del fabricante. Hay que relacionar carga, espacios, altura de montaje y medidas efectivamente instaladas. El dato decisivo puede estar en el local m\u00e1s desfavorable, aunque la potencia total permanezca intacta.<\/span><span class=\"une-t\" lang=\"en\">For this reason, keeping only the manufacturer\u2019s commercial selection is insufficient. The charge, spaces, installation height and measures actually installed must be considered together. The decisive factor may be the most unfavourable room, even if the total capacity remains unchanged.<\/span><span class=\"une-t\" lang=\"fr\">Il ne suffit donc pas d\u2019archiver uniquement la selection commerciale du fabricant. Il faut mettre en relation la charge, les espaces, la hauteur de montage et les mesures effectivement installees. Le facteur decisif peut se trouver dans le local le plus defavorable, m\u00eame si la puissance totale reste inchangee.<\/span><span class=\"une-t\" lang=\"it\">Per questo non e sufficiente archiviare soltanto la selezione commerciale del fabbricante. Occorre mettere in relazione carica, spazi, altezza di montaggio e misure effettivamente installate. Il dato decisivo pu\u00f2 trovarsi nel locale pi\u00f9 sfavorevole, anche se la potenza totale rimane invariata.<\/span><span class=\"une-t\" lang=\"de\">Deshalb reicht es nicht aus, nur die kommerzielle Auswahl des Herstellers abzulegen. F\u00fcllmenge, Raeume, Montagehoehe und tatsaechlich installierte Massnahmen m\u00fcssen gemeinsam betrachtet werden. Entscheidend kann der unguenstigste Raum sein, auch wenn die Gesamtleistung unveraendert bleibt.<\/span><\/p>\r\n<\/div><\/section>\r\n<div aria-label=\"Tabla de documentaci\u00f3n e intervenci\u00f3n t\u00e9cnica\" class=\"une-table-wrap\" role=\"region\" tabindex=\"0\"><table class=\"une-limits-table\"><thead><tr>\r\n<th scope=\"col\"><span class=\"une-t\" lang=\"es\">Supuesto, con potencia t\u00e9rmica RITE inferior a 70 kW<\/span><span class=\"une-t\" lang=\"en\">Case, with RITE thermal capacity below 70 kW<\/span><span class=\"une-t\" lang=\"fr\">Cas avec puissance thermique RITE inferieure \u00e0 70 kW<\/span><span class=\"une-t\" lang=\"it\">Caso con potenza termica RITE inferiore a 70 kW<\/span><span class=\"une-t\" lang=\"de\">Fall bei einer RITE-W\u00e4rmeleistung unter 70 kW<\/span><\/th>\r\n<th scope=\"col\"><span class=\"une-t\" lang=\"es\">Documentaci\u00f3n RSIF<\/span><span class=\"une-t\" lang=\"en\">RSIF documentation<\/span><span class=\"une-t\" lang=\"fr\">Documentation RSIF<\/span><span class=\"une-t\" lang=\"it\">Documentazione RSIF<\/span><span class=\"une-t\" lang=\"de\">RSIF-Dokumentation<\/span><\/th>\r\n<th scope=\"col\"><span class=\"une-t\" lang=\"es\">Intervenci\u00f3n t\u00e9cnica<\/span><span class=\"une-t\" lang=\"en\">Technical involvement<\/span><span class=\"une-t\" lang=\"fr\">Intervention technique<\/span><span class=\"une-t\" lang=\"it\">Intervento tecnico<\/span><span class=\"une-t\" lang=\"de\">Technische Mitwirkung<\/span><\/th><\/tr><\/thead><tbody>\r\n<tr><td><span class=\"une-t\" lang=\"es\">R290\/L3 en r\u00e9gimen general de nivel 2<\/span><span class=\"une-t\" lang=\"en\">R290\/L3 under the general level 2 regime<\/span><span class=\"une-t\" lang=\"fr\">R290\/L3 sous le r\u00e9gime general de niveau 2<\/span><span class=\"une-t\" lang=\"it\">R290\/L3 nel regime generale di livello 2<\/span><span class=\"une-t\" lang=\"de\">R290\/L3 im allgemeinen Regime der Stufe 2<\/span><\/td><td><span class=\"une-t\" lang=\"es\">Proyecto<\/span><span class=\"une-t\" lang=\"en\">Project<\/span><span class=\"une-t\" lang=\"fr\">Projet<\/span><span class=\"une-t\" lang=\"it\">Progetto<\/span><span class=\"une-t\" lang=\"de\">Projekt<\/span><\/td><td><span class=\"une-t\" lang=\"es\">T\u00e9cnico competente y direcci\u00f3n t\u00e9cnica<\/span><span class=\"une-t\" lang=\"en\">Competent technician and technical supervision<\/span><span class=\"une-t\" lang=\"fr\">Technicien comp\u00e9tent et direction technique<\/span><span class=\"une-t\" lang=\"it\">Tecnico competente e direzione tecnica<\/span><span class=\"une-t\" lang=\"de\">Zustaendiger Techniker und technische Leitung<\/span><\/td><\/tr>\r\n<tr><td><span class=\"une-t\" lang=\"es\">L2 distinto de A2L, en r\u00e9gimen general de nivel 2<\/span><span class=\"une-t\" lang=\"en\">L2 other than A2L, under the general level 2 regime<\/span><span class=\"une-t\" lang=\"fr\">L2 autre que A2L, sous le r\u00e9gime general de niveau 2<\/span><span class=\"une-t\" lang=\"it\">L2 diverso da A2L, nel regime generale di livello 2<\/span><span class=\"une-t\" lang=\"de\">L2 au\u00dferhalb A2L im allgemeinen Regime der Stufe 2<\/span><\/td><td><span class=\"une-t\" lang=\"es\">Proyecto<\/span><span class=\"une-t\" lang=\"en\">Project<\/span><span class=\"une-t\" lang=\"fr\">Projet<\/span><span class=\"une-t\" lang=\"it\">Progetto<\/span><span class=\"une-t\" lang=\"de\">Projekt<\/span><\/td><td><span class=\"une-t\" lang=\"es\">T\u00e9cnico competente y direcci\u00f3n t\u00e9cnica<\/span><span class=\"une-t\" lang=\"en\">Competent technician and technical supervision<\/span><span class=\"une-t\" lang=\"fr\">Technicien comp\u00e9tent et direction technique<\/span><span class=\"une-t\" lang=\"it\">Tecnico competente e direzione tecnica<\/span><span class=\"une-t\" lang=\"de\">Zustaendiger Techniker und technische Leitung<\/span><\/td><\/tr>\r\n<tr><td><span class=\"une-t\" lang=\"es\">Nivel 2 por potencia de compresi\u00f3n, sin excepci\u00f3n aplicable<\/span><span class=\"une-t\" lang=\"en\">Level 2 due to compressor power, with no applicable exception<\/span><span class=\"une-t\" lang=\"fr\">Niveau 2 en raison de la puissance des compresseurs, sans exception applicable<\/span><span class=\"une-t\" lang=\"it\">Livello 2 per potenza dei compressori, senza eccezioni applicabili<\/span><span class=\"une-t\" lang=\"de\">Stufe 2 aufgrund der Verdichterleistung, ohne anwendbare Ausnahme<\/span><\/td><td><span class=\"une-t\" lang=\"es\">Proyecto<\/span><span class=\"une-t\" lang=\"en\">Project<\/span><span class=\"une-t\" lang=\"fr\">Projet<\/span><span class=\"une-t\" lang=\"it\">Progetto<\/span><span class=\"une-t\" lang=\"de\">Projekt<\/span><\/td><td><span class=\"une-t\" lang=\"es\">T\u00e9cnico competente y direcci\u00f3n t\u00e9cnica<\/span><span class=\"une-t\" lang=\"en\">Competent technician and technical supervision<\/span><span class=\"une-t\" lang=\"fr\">Technicien comp\u00e9tent et direction technique<\/span><span class=\"une-t\" lang=\"it\">Tecnico competente e direzione tecnica<\/span><span class=\"une-t\" lang=\"de\">Zustaendiger Techniker und technische Leitung<\/span><\/td><\/tr>\r\n<tr><td><span class=\"une-t\" lang=\"es\">A2L dentro de la v\u00eda simplificada y de la justificaci\u00f3n ordinaria<\/span><span class=\"une-t\" lang=\"en\">A2L within the simplified route and ordinary justification<\/span><span class=\"une-t\" lang=\"fr\">A2L dans la voie simplifiee et la justification ordinaire<\/span><span class=\"une-t\" lang=\"it\">A2L nella procedura semplificata e nella giustificazione ordinaria<\/span><span class=\"une-t\" lang=\"de\">A2L im vereinfachten Verfahren und bei regulaerer Begr\u00fcndung<\/span><\/td><td><span class=\"une-t\" lang=\"es\">Memoria y documentaci\u00f3n espec\u00edfica<\/span><span class=\"une-t\" lang=\"en\">Memorandum and specific documentation<\/span><span class=\"une-t\" lang=\"fr\">Memoire et documentation sp\u00e9cifique<\/span><span class=\"une-t\" lang=\"it\">Memoria e documentazione specifica<\/span><span class=\"une-t\" lang=\"de\">Dokumentation und besondere Unterlagen<\/span><\/td><td><span class=\"une-t\" lang=\"es\">Puede firmar el instalador habilitado<\/span><span class=\"une-t\" lang=\"en\">The authorised installer may sign<\/span><span class=\"une-t\" lang=\"fr\">L\u2019installateur habilite peut signer<\/span><span class=\"une-t\" lang=\"it\">pu\u00f2 firmare l\u2019installatore abilitato<\/span><span class=\"une-t\" lang=\"de\">Der zugelassene Installateur kann unterzeichnen<\/span><\/td><\/tr>\r\n<tr><td><span class=\"une-t\" lang=\"es\">A2L acogido al ap\u00e9ndice 4, seg\u00fan el criterio de la consulta 74<\/span><span class=\"une-t\" lang=\"en\">A2L under Appendix 4, according to Consultation 74<\/span><span class=\"une-t\" lang=\"fr\">A2L relevant de l\u2019appendice 4, selon le critere de la consultation 74<\/span><span class=\"une-t\" lang=\"it\">A2L ai sensi dell\u2019appendice 4, secondo il criterio della consultazione 74<\/span><span class=\"une-t\" lang=\"de\">A2L nach Anhang 4 gemaess dem Kriterium der Konsultation 74<\/span><\/td><td><span class=\"une-t\" lang=\"es\">Memoria y justificaci\u00f3n correspondiente<\/span><span class=\"une-t\" lang=\"en\">Memorandum and corresponding justification<\/span><span class=\"une-t\" lang=\"fr\">Memoire et justification correspondante<\/span><span class=\"une-t\" lang=\"it\">Memoria e relativa giustificazione<\/span><span class=\"une-t\" lang=\"de\">Dokumentation und entsprechende Begr\u00fcndung<\/span><\/td><td><span class=\"une-t\" lang=\"es\">T\u00e9cnico competente<\/span><span class=\"une-t\" lang=\"en\">Competent technician<\/span><span class=\"une-t\" lang=\"fr\">Technicien comp\u00e9tent<\/span><span class=\"une-t\" lang=\"it\">Tecnico competente<\/span><span class=\"une-t\" lang=\"de\">Zustaendiger Techniker<\/span><\/td><\/tr>\r\n<tr><td><span class=\"une-t\" lang=\"es\">A2L con an\u00e1lisis de riesgos, acogido al art\u00edculo 21.4<\/span><span class=\"une-t\" lang=\"en\">A2L with risk analysis, under Article 21(4)<\/span><span class=\"une-t\" lang=\"fr\">A2L avec analyse des risques, relevant de l\u2019article 21.4<\/span><span class=\"une-t\" lang=\"it\">A2L con analisi dei rischi, ai sensi dell\u2019articolo 21.4<\/span><span class=\"une-t\" lang=\"de\">A2L mit Risikoanalyse nach Artikel 21.4<\/span><\/td><td><span class=\"une-t\" lang=\"es\">Memoria y documentaci\u00f3n del art\u00edculo 21.3<\/span><span class=\"une-t\" lang=\"en\">Memorandum and documentation under Article 21(3)<\/span><span class=\"une-t\" lang=\"fr\">Memoire et documentation de l\u2019article 21.3<\/span><span class=\"une-t\" lang=\"it\">Memoria e documentazione dell\u2019articolo 21.3<\/span><span class=\"une-t\" lang=\"de\">Dokumentation und Unterlagen nach Artikel 21.3<\/span><\/td><td><span class=\"une-t\" lang=\"es\">T\u00e9cnico competente; empresa de nivel 2<\/span><span class=\"une-t\" lang=\"en\">Competent technician; level 2 company<\/span><span class=\"une-t\" lang=\"fr\">Technicien comp\u00e9tent ; entreprise de niveau 2<\/span><span class=\"une-t\" lang=\"it\">Tecnico competente; impresa di livello 2<\/span><span class=\"une-t\" lang=\"de\">Zustaendiger Techniker; Unternehmen der Stufe 2<\/span><\/td><\/tr>\r\n<tr><td><span class=\"une-t\" lang=\"es\">R290 que cumple \u00edntegramente la IF-20<\/span><span class=\"une-t\" lang=\"en\">R290 fully compliant with IF-20<\/span><span class=\"une-t\" lang=\"fr\">R290 respectant integralement l\u2019IF-20<\/span><span class=\"une-t\" lang=\"it\">R290 conforme integralmente alla IF-20<\/span><span class=\"une-t\" lang=\"de\">R290, das IF-20 vollstaendig erfuellt<\/span><\/td><td><span class=\"une-t\" lang=\"es\">Memoria, dentro del tramo RITE correspondiente<\/span><span class=\"une-t\" lang=\"en\">Memorandum, within the applicable RITE range<\/span><span class=\"une-t\" lang=\"fr\">Memoire, dans la plage RITE correspondante<\/span><span class=\"une-t\" lang=\"it\">Memoria, nell\u2019intervallo RITE corrispondente<\/span><span class=\"une-t\" lang=\"de\">Dokumentation innerhalb des entsprechenden RITE-Bereichs<\/span><\/td><td><span class=\"une-t\" lang=\"es\">Sin obligaci\u00f3n general de t\u00e9cnico por utilizar R290<\/span><span class=\"une-t\" lang=\"en\">No general requirement for a technician merely because R290 is used<\/span><span class=\"une-t\" lang=\"fr\">Aucune obligation generale de technicien du seul fait de l\u2019utilisation du R290<\/span><span class=\"une-t\" lang=\"it\">Nessun obbligo generale di tecnico per il solo utilizzo di R290<\/span><span class=\"une-t\" lang=\"de\">Keine allgemeine Technikerpflicht allein wegen der Verwendung von R290<\/span><\/td><\/tr>\r\n<\/tbody><\/table><\/div>\r\n<section class=\"une-page-group une-page-group--separated\"><div class=\"une-column\">\r\n<p><span class=\"une-t\" lang=\"es\">El expediente debe acreditar ambos reglamentos. Cuando el RITE permite memoria y el RSIF exige proyecto, cabe preparar ambos documentos o integrar voluntariamente sus contenidos en un proyecto \u00fanico. La gu\u00eda ministerial reconoce expresamente esa posibilidad.<\/span><span class=\"une-t\" lang=\"en\">The file must demonstrate compliance with both regulations. Where the RITE allows a memorandum and the RSIF requires a project, both documents may be prepared or their contents may be voluntarily integrated into a single project. The ministerial guide expressly recognises this possibility.<\/span><span class=\"une-t\" lang=\"fr\">Le dossier doit demontrer le respect des deux reglements. Lorsque le RITE permet une m\u00e9moire et que le RSIF exige un projet, il est possible de preparer les deux documents ou d\u2019integrer volontairement leur contenu dans un projet unique. Le guide ministeriel reconnait expressement cette possibilite.<\/span><span class=\"une-t\" lang=\"it\">Il fascicolo deve dimostrare il rispetto di entrambi i regolamenti. Quando il RITE consente una memoria e il RSIF richiede un progetto, si possono predisporre entrambi i documenti oppure integrarli volontariamente in un unico progetto. La guida ministeriale riconosce espressamente questa possibilit\u00e0.<\/span><span class=\"une-t\" lang=\"de\">Die Unterlagen m\u00fcssen die Einhaltung beider Regelwerke nachweisen. Wenn das RITE eine Dokumentation erlaubt und das RSIF ein Projekt verlangt, k\u00f6nnen beide Dokumente erstellt oder ihre Inhalte freiwillig in einem einzigen Projekt zusammengefuehrt werden. Der Leitfaden des Ministeriums erkennt diese Moeglichkeit ausdruecklich an.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">La documentaci\u00f3n debe existir antes de ejecutar. Para la puesta en servicio, el art\u00edculo 21.5 re\u00fane la documentaci\u00f3n frigor\u00edfica y la del RITE ante el \u00f3rgano auton\u00f3mico responsable de este \u00faltimo, conforme al procedimiento aplicable.<\/span><span class=\"une-t\" lang=\"en\">The documentation must exist before work is carried out. For commissioning, Article 21(5) brings together the refrigeration documentation and the RITE documentation for submission to the regional authority responsible for the latter, in accordance with the applicable procedure.<\/span><span class=\"une-t\" lang=\"fr\">La documentation doit exister avant l\u2019ex\u00e9cution. Pour la mise en service, l\u2019article 21.5 regroupe la documentation frigorifique et celle du RITE aupres de l\u2019organisme de la communaut\u00e9 autonome responsable de ce dernier, conformement \u00e0 la procedure applicable.<\/span><span class=\"une-t\" lang=\"it\">La documentazione deve esistere prima dell\u2019esecuzione. Per la messa in servizio, l\u2019articolo 21.5 riunisce la documentazione frigorifera e quella del RITE presso l\u2019organo autonomico responsabile di quest\u2019ultimo, secondo la procedura applicabile.<\/span><span class=\"une-t\" lang=\"de\">Die Dokumentation muss vor der Ausf\u00fchrung vorliegen. Fuer die Inbetriebnahme fasst Artikel 21.5 die kaeltetechnischen Unterlagen und die RITE-Unterlagen zusammen, die nach dem anwendbaren Verfahren bei der f\u00fcr das RITE zust\u00e4ndigen Regionalbehoerde einzureichen sind.<\/span><\/p>\r\n<\/div><div class=\"une-column\">\r\n<p><span class=\"une-t\" lang=\"es\">Una tramitaci\u00f3n conjunta no elimina ninguna de las justificaciones exigibles.<\/span><span class=\"une-t\" lang=\"en\">A joint filing does not remove any of the required justifications.<\/span><span class=\"une-t\" lang=\"fr\">Une procedure commune ne supprime aucune des justifications requises.<\/span><span class=\"une-t\" lang=\"it\">Una procedura congiunta non elimina nessuna delle giustificazioni richieste.<\/span><span class=\"une-t\" lang=\"de\">Ein gemeinsames Verfahren entfaellt keine der erforderlichen Begr\u00fcndungen.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">La decisi\u00f3n profesional empieza antes de pedir una firma: identificar el sistema, clasificar el refrigerante, determinar las cargas, comprobar las potencias y justificar el emplazamiento. Despu\u00e9s se elige la v\u00eda documental. Hacerlo al rev\u00e9s deja demasiadas decisiones de seguridad para cuando las tuber\u00edas ya est\u00e1n montadas.<\/span><span class=\"une-t\" lang=\"en\">The professional decision begins before requesting a signature: identify the system, classify the refrigerant, determine the charges, check the power ratings and justify the location. The documentation route is chosen afterwards. Doing it the other way round leaves too many safety decisions until after the pipework has been installed.<\/span><span class=\"une-t\" lang=\"fr\">La decision professionnelle commence avant de demander une signature : identifier le syst\u00e8me, classer le refrigerant, determiner les charges, v\u00e9rifier les puissances et justifier l\u2019emplacement. La voie documentaire est choisie ensuite. Proceder \u00e0 l\u2019inverse laisse trop de decisions de s\u00e9curit\u00e9 au moment ou les tuyauteries sont d\u00e9j\u00e0 installees.<\/span><span class=\"une-t\" lang=\"it\">La decisione professionale inizia prima di chiedere una firma: identificare il sistema, classificare il refrigerante, determinare le cariche, verificare le potenze e giustificare il luogo di installazione. Solo dopo si sceglie la procedura documentale. Fare il contrario lascia troppe decisioni di sicurezza a quando le tubazioni sono gia montate.<\/span><span class=\"une-t\" lang=\"de\">Die fachliche Entscheidung beginnt vor der Anforderung einer Unterschrift: System identifizieren, K\u00e4ltemittel einstufen, F\u00fcllmengen bestimmen, Leistungen pr\u00fcfen und den Aufstellort begruenden. Erst danach wird der Dokumentationsweg gewaehlt. Wer umgekehrt vorgeht, verschiebt zu viele Sicherheitsentscheidungen auf einen Zeitpunkt, zu dem die Rohrleitungen bereits montiert sind.<\/span><\/p>\r\n<\/div><\/section>\r\n<section class=\"rite-conclusion\"><h2 class=\"rite-conclusion-title\"><span class=\"une-t\" lang=\"es\">Conclusi\u00f3n t\u00e9cnica<\/span><span class=\"une-t\" lang=\"en\">Technical conclusion<\/span><span class=\"une-t\" lang=\"fr\">Conclusion technique<\/span><span class=\"une-t\" lang=\"it\">Conclusione tecnica<\/span><span class=\"une-t\" lang=\"de\">Technisches Fazit<\/span><\/h2>\r\n<p><span class=\"une-t\" lang=\"es\">El umbral de 70 kW del RITE no determina, por s\u00ed solo, la documentaci\u00f3n exigible a una instalaci\u00f3n con circuito frigor\u00edfico. La decisi\u00f3n requiere comprobar simult\u00e1neamente la potencia t\u00e9rmica, la potencia el\u00e9ctrica instalada en los compresores, el refrigerante, su carga y las condiciones de emplazamiento.<\/span><span class=\"une-t\" lang=\"en\">The RITE 70 kW threshold does not, by itself, determine the documentation required for an installation with a refrigeration circuit. The decision requires simultaneous verification of thermal capacity, electrical power installed in the compressors, refrigerant, charge and installation conditions.<\/span><span class=\"une-t\" lang=\"fr\">Le seuil de 70 kW du RITE ne determine pas, \u00e0 lui seul, la documentation exig\u00e9e pour une installation comportant un circuit frigorifique. La decision exige de v\u00e9rifier simultanement la puissance thermique, la puissance \u00e9lectrique install\u00e9e dans les compresseurs, le refrigerant, sa charge et les conditions d\u2019implantation.<\/span><span class=\"une-t\" lang=\"it\">La soglia di 70 kW del RITE non determina, da sola, la documentazione richiesta per un impianto con circuito frigorifero. La decisione richiede di verificare simultaneamente la potenza termica, la potenza elettrica installata nei compressori, il refrigerante, la sua carica e le condizioni di installazione.<\/span><span class=\"une-t\" lang=\"de\">Der 70-kW-Grenzwert des RITE bestimmt f\u00fcr sich genommen nicht die f\u00fcr eine Anlage mit K\u00e4ltekreislauf erforderlichen Unterlagen. Die Entscheidung erfordert eine gleichzeitige Pr\u00fcfung der W\u00e4rmeleistung, der installierten elektrischen Verdichterleistung, des Kaeltemittels, seiner F\u00fcllmenge und der Aufstellbedingungen.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">Cuando corresponde el r\u00e9gimen general de nivel 2 del RSIF, la instalaci\u00f3n necesita proyecto y direcci\u00f3n t\u00e9cnica, aunque su potencia t\u00e9rmica sea inferior a 70 kW. Sin embargo, aplicar esta exigencia autom\u00e1ticamente a cualquier equipo con R290 o A2L ser\u00eda incorrecto: deben revisarse las exclusiones y los reg\u00edmenes espec\u00edficos previstos en el reglamento.<\/span><span class=\"une-t\" lang=\"en\">Where the general level 2 regime of the RSIF applies, the installation requires a project and technical supervision, even if its thermal capacity is below 70 kW. However, applying this requirement automatically to every unit using R290 or A2L would be incorrect: the exclusions and specific regimes provided for in the regulation must be checked.<\/span><span class=\"une-t\" lang=\"fr\">Lorsque le r\u00e9gime general de niveau 2 du RSIF s\u2019appliqu\u00e9, l\u2019installation n\u00e9cessite un projet et une direction technique, m\u00eame si sa puissance thermique est inferieure \u00e0 70 kW. Toutefois, appliquer automatiquement cette exigence \u00e0 tout appareil utilisant du R290 ou un refrigerant A2L serait incorrect : il faut examiner les exclusions et les regimes specifiques prevus par le r\u00e8glement.<\/span><span class=\"une-t\" lang=\"it\">Quando si applica il regime generale di livello 2 del RSIF, l\u2019impianto necessita di un progetto e di una direzione tecnica, anche se la potenza termica e inferiore a 70 kW. Tuttavia, applicare automaticamente tale requisito a qualsiasi apparecchio con R290 o A2L sarebbe errato: occorre verificare le esclusioni e i regimi specifici previsti dal regolamento.<\/span><span class=\"une-t\" lang=\"de\">Wenn das allgemeine Regime der Stufe 2 des RSIF gilt, benoetigt die Anlage ein Projekt und eine technische Leitung, auch wenn ihre W\u00e4rmeleistung unter 70 kW liegt. Diese Anforderung automatisch auf jedes Ger\u00e4t mit R290 oder A2L anzuwenden, w\u00e4re jedoch falsch: Die im Regelwerk vorgesehenen Ausnahmen und Sonderregime m\u00fcssen gepr\u00fcft werden.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">La IF-20 permite determinadas instalaciones indirectas con equipos compactos bajo condiciones concretas. Por su parte, el r\u00e9gimen A2L contempla situaciones en las que basta una memoria, pero exige t\u00e9cnico competente para justificar las medidas de seguridad o elaborar el an\u00e1lisis de riesgos correspondiente. Necesitar t\u00e9cnico no equivale necesariamente a necesitar proyecto.<\/span><span class=\"une-t\" lang=\"en\">IF-20 allows certain indirect installations with compact units under specific conditions. The A2L regime, for its part, includes situations in which a memorandum is sufficient but requires a competent technician to justify the safety measures or prepare the corresponding risk analysis. Requiring a technician does not necessarily mean that a project is required.<\/span><span class=\"une-t\" lang=\"fr\">L\u2019IF-20 permet certaines installations indirectes avec des appareils compacts sous des conditions precises. Le r\u00e9gime A2L pr\u00e9voit, quant \u00e0 lui, des situations ou une m\u00e9moire suffit, mais exige un technicien comp\u00e9tent pour justifier les mesures de s\u00e9curit\u00e9 ou elaborer l\u2019analyse des risques correspondante. La n\u00e9cessite d\u2019un technicien n\u2019implique pas necessairement celle d\u2019un projet.<\/span><span class=\"une-t\" lang=\"it\">La IF-20 consente determinate installazioni indirette con apparecchi compatti a condizioni specifiche. Il regime A2L contempla invece situazioni in cui basta una memoria, ma richiede un tecnico competente per giustificare le misure di sicurezza o redigere la relativa analisi dei rischi. La necessita di un tecnico non equivale necessariamente alla necessita di un progetto.<\/span><span class=\"une-t\" lang=\"de\">IF-20 erlaubt bestimmte indirekte Anlagen mit kompakten Geraeten unter konkreten Bedingungen. Das A2L-Regime sieht seinerseits F\u00e4lle vor, in denen eine Dokumentation ausreicht, jedoch ein zust\u00e4ndiger Techniker die Sicherheitsmassnahmen begruenden oder die entsprechende Risikoanalyse erstellen muss. Die Notwendigkeit eines Technikers bedeutet nicht zwingend, dass ein Projekt erforderlich ist.<\/span><\/p>\r\n<p><span class=\"une-t\" lang=\"es\">La comprobaci\u00f3n debe realizarse antes de seleccionar definitivamente los equipos y ejecutar las tuber\u00edas. La documentaci\u00f3n debe reflejar la configuraci\u00f3n ejecutada, la carga final y las protecciones verificadas. Una memoria insuficiente no queda subsanada por estar registrada, ni un proyecto convierte en admisible una soluci\u00f3n que incumple las condiciones de seguridad.<\/span><span class=\"une-t\" lang=\"en\">The assessment must be carried out before the equipment is finally selected and the pipework installed. The documentation must reflect the configuration as built, the final charge and the verified protective measures. An inadequate memorandum is not remedied by being registered, and a project does not make a solution that fails to meet safety conditions acceptable.<\/span><span class=\"une-t\" lang=\"fr\">La v\u00e9rification doit etre effectuee avant la selection d\u00e9finitive des appareils et la pose des tuyauteries. La documentation doit refleter la configuration ex\u00e9cut\u00e9e, la charge finale et les protections verifiees. Une m\u00e9moire insuffisante n\u2019est pas regularisee par son enregistrement, pas plus qu\u2019un projet ne rend admissible une solution qui ne respecte pas les conditions de s\u00e9curit\u00e9.<\/span><span class=\"une-t\" lang=\"it\">La verifica deve essere effettuata prima della selezione definitiva delle apparecchiature e della posa delle tubazioni. La documentazione deve riflettere la configurazione realizzata, la carica finale e le protezioni verificate. Una memoria insufficiente non viene sanata dalla registrazione, cosi come un progetto non rende ammissibile una soluzione che non rispetta le condizioni di sicurezza.<\/span><span class=\"une-t\" lang=\"de\">Die Pr\u00fcfung muss erfolgen, bevor die Ger\u00e4te endgueltig ausgewaehlt und die Rohrleitungen verlegt werden. Die Dokumentation muss die ausgef\u00fchrte Konfiguration, die endgueltige F\u00fcllmenge und die geprueften Schutzmassnahmen widerspiegeln. Eine unzureichende Dokumentation wird durch ihre Registrierung nicht geheilt, und ein Projekt macht eine Loesung, die die Sicherheitsbedingungen nicht erfuellt, nicht zul\u00e4ssig.<\/span><\/p>\r\n<\/section>\r\n<div class=\"une-multilingual-motto\"><p>Evita ambientes poco ventilados y a quien no te mantenga informado.<\/p><\/div>\r\n<aside aria-label=\"Autor\" class=\"pree-author-card pree-author-card--bottom\"><div class=\"pree-author-identity\"><img loading=\"lazy\" alt=\"Jos\u00e9 Jes\u00fas Arboledas Herranz\" class=\"keyter-author-compact__photo\" decoding=\"async\" height=\"58\" loading=\"lazy\" src=\"https:\/\/www.keyter.com\/wp-content\/uploads\/2026\/10\/1791098996839.jpg\" width=\"58\"\/><div class=\"keyter-author-compact__content\"><p class=\"keyter-author-compact__name\">Jos\u00e9 Jes\u00fas Arboledas Herranz<\/p><p class=\"keyter-author-compact__meta\">Instituto Ent\u00e1lpico Espa\u00f1ol<\/p><p class=\"keyter-author-compact__bio\"><span class=\"une-t\" lang=\"es\">Miembro ASHRAE Spain Chapter<\/span><span class=\"une-t\" lang=\"en\">ASHRAE Spain Chapter member<\/span><span class=\"une-t\" lang=\"fr\">Membre de l\u2019ASHRAE Spain Chapter<\/span><span class=\"une-t\" lang=\"it\">Membro di ASHRAE Spain Chapter<\/span><span class=\"une-t\" lang=\"de\">Mitglied des ASHRAE Spain Chapter<\/span><\/p><p class=\"keyter-author-compact__links\"><a href=\"mailto:iee@institutoentalpico.com\">iee@institutoentalpico.com<\/a> \u00b7 <a href=\"https:\/\/lnkd.in\/p\/emk_G3xH\" rel=\"noopener noreferrer\" target=\"_blank\">LinkedIn<\/a> \u00b7 <a href=\"https:\/\/www.youtube.com\/@institutoentalpicoespa%C3%B1ol\" rel=\"noopener noreferrer\" target=\"_blank\">YouTube<\/a><\/p><\/div><a class=\"pree-iee-logo--author\" href=\"https:\/\/sites.google.com\/view\/institutoentalpico\" rel=\"noopener noreferrer\" target=\"_blank\"><img loading=\"lazy\" alt=\"Instituto Ent\u00e1lpico Espa\u00f1ol\" decoding=\"async\" height=\"70\" loading=\"lazy\" src=\"https:\/\/www.keyter.com\/wp-content\/uploads\/2026\/10\/institutoentalpico-logo.webp\" width=\"180\"\/><\/a><\/div><\/aside>\r\n<nav aria-label=\"Documentaci\u00f3n oficial\" class=\"une-norm-tags une-norm-tags--bottom\"><div class=\"une-norm-tags__grid\"><a class=\"une-norm-tags__item\" href=\"https:\/\/www.boe.es\/buscar\/pdf\/2007\/BOE-A-2007-15820-consolidado.pdf\" rel=\"noopener noreferrer\" target=\"_blank\">RITE \u00b7 RD 1027\/2007 \u00b7 BOE PDF<\/a><a class=\"une-norm-tags__item\" href=\"https:\/\/www.boe.es\/buscar\/pdf\/2019\/BOE-A-2019-15228-consolidado.pdf\" rel=\"noopener noreferrer\" target=\"_blank\">RSIF \u00b7 RD 552\/2019 \u00b7 BOE PDF<\/a><a class=\"une-norm-tags__item\" href=\"https:\/\/industria.gob.es\/Calidad-Industrial\/seguridadindustrial\/instalacionesindustriales\/instaciones-frigorificas\/Documents\/GUIA%20IF%20NIPO%20v4.pdf\" rel=\"noopener noreferrer\" target=\"_blank\">Guia RSIF \u00b7 Consulta 74 \u00b7 Ministerio<\/a><\/div><\/nav><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d934c8e elementor-widget elementor-widget-spacer\" data-id=\"d934c8e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-a89c9cd elementor-section-full_width elementor-section-height-min-height elementor-section-stretched elementor-section-height-default elementor-section-items-middle parallax_section_no qode_elementor_container_no\" data-id=\"a89c9cd\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;stretch_section&quot;:&quot;section-stretched&quot;}\">\n\t\t\t\t\t\t\t<div class=\"elementor-background-overlay\"><\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-f55bf26\" data-id=\"f55bf26\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-97a0a59 elementor-widget elementor-widget-heading\" data-id=\"97a0a59\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><span>M\u00e1s art\u00edculos<\/span><\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a184ad8 elementor-widget elementor-widget-text-editor\" data-id=\"a184ad8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00bfTe interesan nuestras noticias, art\u00edculos y actualizaciones? L\u00e9elo todo y mantente al d\u00eda.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-195ae25 elementor-align-center elementor-widget elementor-widget-button\" data-id=\"195ae25\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.keyter.com\/es\/akademy\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t<span class=\"elementor-button-icon\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-arrow-circle-right\"><\/i>\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">ART\u00cdCULOS<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-fb8709f elementor-section-full_width elementor-section-height-min-height elementor-section-stretched elementor-section-height-default elementor-section-items-middle parallax_section_no qode_elementor_container_no\" data-id=\"fb8709f\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;stretch_section&quot;:&quot;section-stretched&quot;}\">\n\t\t\t\t\t\t\t<div class=\"elementor-background-overlay\"><\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-f31a329\" data-id=\"f31a329\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-65b04ad elementor-widget elementor-widget-text-editor\" data-id=\"65b04ad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>M\u00c1S SOBRE KEYTER<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec720cf elementor-widget elementor-widget-text-editor\" data-id=\"ec720cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h4 style=\"font-size: 40px\">\u00bfEn qu\u00e9 estas interesado?<\/h4>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9c2cb42 elementor-widget elementor-widget-image\" data-id=\"9c2cb42\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"369\" height=\"9\" src=\"https:\/\/www.keyter.com\/wp-content\/uploads\/2020\/10\/line-leaf.svg\" class=\"attachment-medium size-medium wp-image-45826\" alt=\"\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-0e282af elementor-section-boxed elementor-section-height-default elementor-section-height-default parallax_section_no qode_elementor_container_no\" data-id=\"0e282af\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-25 elementor-inner-column elementor-element elementor-element-76e97bc\" data-id=\"76e97bc\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7dff960 elementor-align-center elementor-widget elementor-widget-button\" data-id=\"7dff960\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.keyter.com\/es\/nuestra-historia\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t<span class=\"elementor-button-icon\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-arrow-circle-right\"><\/i>\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\"> NUESTRA HISTORIA<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-25 elementor-inner-column elementor-element elementor-element-1b6d582\" data-id=\"1b6d582\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-696ac41 elementor-align-center elementor-widget elementor-widget-button\" data-id=\"696ac41\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.keyter.com\/es\/productos\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t<span class=\"elementor-button-icon\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-arrow-circle-right\"><\/i>\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">GAMA DE PRODUCTOS<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-25 elementor-inner-column elementor-element elementor-element-f79bbd0\" data-id=\"f79bbd0\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-fb9cf4c elementor-align-center elementor-widget elementor-widget-button\" data-id=\"fb9cf4c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.keyter.com\/es\/referencias\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t<span class=\"elementor-button-icon\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-arrow-circle-right\"><\/i>\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">REFERENCIAS<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-25 elementor-inner-column elementor-element elementor-element-71f934f\" data-id=\"71f934f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-77795df elementor-align-center elementor-widget elementor-widget-button\" data-id=\"77795df\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.keyter.com\/es\/empleo\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t<span class=\"elementor-button-icon\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-arrow-circle-right\"><\/i>\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">EMPLEO<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Linkedin Facebook X-twitter Youtube RITE, LA TRAMPA DE LOS 70kWRITE: THE 70 kW TRAPRITE : LE PI\u00c8GE DES 70 kWRITE: LA TRAPPOLA DEI 70 kWRITE: DIE 70-kW-FALLE Jos\u00e9 Jes\u00fas Arboledas Herranz Instituto Ent\u00e1lpico Espa\u00f1ol Miembro ASHRAE Spain ChapterASHRAE Spain Chapter memberMembre de l\u2019ASHRAE Spain ChapterMembro&#8230;<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"content-type":"","inline_featured_image":false,"footnotes":""},"class_list":["post-99711","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>RITE, la Trampa de los 70kW - Keyter<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.keyter.com\/es\/rite-la-trampa-de-los-70kw\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"RITE, la Trampa de los 70kW - Keyter\" \/>\n<meta property=\"og:description\" content=\"Linkedin Facebook X-twitter Youtube RITE, LA TRAMPA DE LOS 70kWRITE: THE 70 kW TRAPRITE : LE PI\u00c8GE DES 70 kWRITE: LA TRAPPOLA DEI 70 kWRITE: DIE 70-kW-FALLE Jos\u00e9 Jes\u00fas Arboledas Herranz Instituto Ent\u00e1lpico Espa\u00f1ol Miembro ASHRAE Spain ChapterASHRAE Spain Chapter memberMembre de l\u2019ASHRAE Spain ChapterMembro...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.keyter.com\/es\/rite-la-trampa-de-los-70kw\/\" \/>\n<meta property=\"og:site_name\" content=\"Keyter\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-16T11:05:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.keyter.com\/wp-content\/uploads\/2020\/11\/line-leaf-single-right.svg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"53 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.keyter.com\\\/es\\\/rite-la-trampa-de-los-70kw\\\/\",\"url\":\"https:\\\/\\\/www.keyter.com\\\/es\\\/rite-la-trampa-de-los-70kw\\\/\",\"name\":\"RITE, la Trampa de los 70kW - Keyter\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.keyter.com\\\/es\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.keyter.com\\\/es\\\/rite-la-trampa-de-los-70kw\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.keyter.com\\\/es\\\/rite-la-trampa-de-los-70kw\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.keyter.com\\\/wp-content\\\/uploads\\\/2020\\\/11\\\/line-leaf-single-right.svg\",\"datePublished\":\"2026-11-16T08:53:16+00:00\",\"dateModified\":\"2026-11-16T11:05:49+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.keyter.com\\\/es\\\/rite-la-trampa-de-los-70kw\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.keyter.com\\\/es\\\/rite-la-trampa-de-los-70kw\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/www.keyter.com\\\/es\\\/rite-la-trampa-de-los-70kw\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.keyter.com\\\/wp-content\\\/uploads\\\/2020\\\/11\\\/line-leaf-single-right.svg\",\"contentUrl\":\"https:\\\/\\\/www.keyter.com\\\/wp-content\\\/uploads\\\/2020\\\/11\\\/line-leaf-single-right.svg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.keyter.com\\\/es\\\/rite-la-trampa-de-los-70kw\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.keyter.com\\\/es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"RITE, la Trampa de los 70kW\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.keyter.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/www.keyter.com\\\/es\\\/\",\"name\":\"Keyter\",\"description\":\"Leading thermodynamic technologies\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.keyter.com\\\/es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"RITE, la Trampa de los 70kW - Keyter","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.keyter.com\/es\/rite-la-trampa-de-los-70kw\/","og_locale":"es_ES","og_type":"article","og_title":"RITE, la Trampa de los 70kW - Keyter","og_description":"Linkedin Facebook X-twitter Youtube RITE, LA TRAMPA DE LOS 70kWRITE: THE 70 kW TRAPRITE : LE PI\u00c8GE DES 70 kWRITE: LA TRAPPOLA DEI 70 kWRITE: DIE 70-kW-FALLE Jos\u00e9 Jes\u00fas Arboledas Herranz Instituto Ent\u00e1lpico Espa\u00f1ol Miembro ASHRAE Spain ChapterASHRAE Spain Chapter memberMembre de l\u2019ASHRAE Spain ChapterMembro...","og_url":"https:\/\/www.keyter.com\/es\/rite-la-trampa-de-los-70kw\/","og_site_name":"Keyter","article_modified_time":"2026-11-16T11:05:49+00:00","og_image":[{"url":"https:\/\/www.keyter.com\/wp-content\/uploads\/2020\/11\/line-leaf-single-right.svg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Tiempo de lectura":"53 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.keyter.com\/es\/rite-la-trampa-de-los-70kw\/","url":"https:\/\/www.keyter.com\/es\/rite-la-trampa-de-los-70kw\/","name":"RITE, la Trampa de los 70kW - Keyter","isPartOf":{"@id":"https:\/\/www.keyter.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.keyter.com\/es\/rite-la-trampa-de-los-70kw\/#primaryimage"},"image":{"@id":"https:\/\/www.keyter.com\/es\/rite-la-trampa-de-los-70kw\/#primaryimage"},"thumbnailUrl":"https:\/\/www.keyter.com\/wp-content\/uploads\/2020\/11\/line-leaf-single-right.svg","datePublished":"2026-11-16T08:53:16+00:00","dateModified":"2026-11-16T11:05:49+00:00","breadcrumb":{"@id":"https:\/\/www.keyter.com\/es\/rite-la-trampa-de-los-70kw\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.keyter.com\/es\/rite-la-trampa-de-los-70kw\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.keyter.com\/es\/rite-la-trampa-de-los-70kw\/#primaryimage","url":"https:\/\/www.keyter.com\/wp-content\/uploads\/2020\/11\/line-leaf-single-right.svg","contentUrl":"https:\/\/www.keyter.com\/wp-content\/uploads\/2020\/11\/line-leaf-single-right.svg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.keyter.com\/es\/rite-la-trampa-de-los-70kw\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.keyter.com\/es\/"},{"@type":"ListItem","position":2,"name":"RITE, la Trampa de los 70kW"}]},{"@type":"WebSite","@id":"https:\/\/www.keyter.com\/es\/#website","url":"https:\/\/www.keyter.com\/es\/","name":"Keyter","description":"Leading thermodynamic technologies","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.keyter.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"}]}},"_links":{"self":[{"href":"https:\/\/www.keyter.com\/es\/wp-json\/wp\/v2\/pages\/99711","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.keyter.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.keyter.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.keyter.com\/es\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.keyter.com\/es\/wp-json\/wp\/v2\/comments?post=99711"}],"version-history":[{"count":3,"href":"https:\/\/www.keyter.com\/es\/wp-json\/wp\/v2\/pages\/99711\/revisions"}],"predecessor-version":[{"id":99730,"href":"https:\/\/www.keyter.com\/es\/wp-json\/wp\/v2\/pages\/99711\/revisions\/99730"}],"wp:attachment":[{"href":"https:\/\/www.keyter.com\/es\/wp-json\/wp\/v2\/media?parent=99711"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}